k‐space detection and correction of physiological artifacts in fMRI
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Signal phase variations caused by physiology are a major source of instability in fMRI images produced by multiple RF pulses. k‐Space phase variation maps show cyclic phase variations at the frequency of respiration combined with a cardiac variation of lower amplitude. The amplitude of the variation increases with gradient echo time and proximity to the chest, suggesting that the dominant cause of the phase variation is a B0 shift (∼0.01 ppm) produced by movement of organs in the chest. A simple k‐space phase correction method is proposed and demonstrated for FLASH fMRI. The retrospective method requires no pulse sequence modification, and is more effective than navigator echo correction. Physiological noise is dramatically reduced, especially at inferior slice locations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Movement‐Related effects in fMRI time‐series
Friston, K. J., Williams, S., Howard, R., Frackowiak, R. S. J., & Turner, R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350312 · Cited by 3,774
Cited by
Methods for cleaning the BOLD fMRI signal
Caballero-Gaudes, C., & Reynolds, R. C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.12.018 · Cited by 542
“Additionally, thoracic movements during breathing result in respiratory-dependent changes in the magnetic field in the head volume that produce a shift in the phase of the MR image (Brosch et al., 2002; Raj et al., 2000; 2001; van de Moortele et al., 2002; Wowk et al., 1997).”
Shmueli, K., van Gelderen, P., de Zwart, J. A., Horovitz, S. G., Fukunaga, M., Jansma, J. M., & Duyn, J. H. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.037 · Cited by 541
Investigation of Low Frequency Drift in fMRI Signal
Smith, A. M., Lewis, B. K., Ruttimann, U. E., Ye, F. Q., Sinnwell, T. M., Yang, Y., Duyn, J. H., & Frank, J. A. (1999) · NeuroImage · doi:10.1006/nimg.1999.0435 · Cited by 313
Ye, F. Q., Frank, J. A., Weinberger, D. R., & McLaughlin, A. C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200007)44:1<92::aid-mrm14>3.0.co;2-m · Cited by 309
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Metadata
- Authors
- Wowk, B., McIntyre, M. C., & Saunders, J. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1997-12
- Volume
- 38
- Issue
- 6
- Pages
- 1029-1034
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2082159979
- Cited by
- 79
- References
- 1
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.