Removal of local field gradient artifacts in T2*‐weighted images at high fields by gradient‐echo slice excitation profile imaging
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Development of high magnetic field MRI techniques is hampered by the significant artifacts produced by B 0 field inhomogeneities in the excited slices. A technique, gradient‐echo slice excitation profile imaging (GESEPI), is presented for recovering the signal lost caused by intravoxel phase dispersion in T 2*‐weighted images. This technique superimposes an incremental gradient offset on the slice refocusing gradient to sample Jr‐space over the full range of spatial frequencies of the excitation profile. A third Fourier transform of the initial two‐dimensional image set generates an image set in which the artifacts produced by the low‐order B 0 inhomogeneity field gradients in the sample are separated and removed from the high‐order microscopic field gradients responsible for T 2* contrast. Application to high field brain imaging, at 3.0 T for human and at 9.4 T for immature rat imaging demonstrates the significant improvement in quality of the T 2*‐weighted contrast images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Cited by
Spiral‐in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
Glover, G. H., & Law, C. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1222 · Cited by 599
Metal-Induced Artifacts in MRI
Hargreaves, B. A., Worters, P. W., Pauly, K. B., Pauly, J. M., Koch, K. M., & Gold, G. E. (2011) · American Journal of Roentgenology · doi:10.2214/ajr.11.7364 · Cited by 559
Susceptibility-Induced Loss of Signal: Comparing PET and fMRI on a Semantic Task
Devlin, J. T., Russell, R. P., Davis, M. H., Price, C. J., Wilson, J., Moss, H. E., Matthews, P. M., & Tyler, L. K. (2000) · NeuroImage · doi:10.1006/nimg.2000.0595 · Cited by 439
SEMAC: Slice encoding for metal artifact correction in MRI
Lu, W., Pauly, K. B., Gold, G. E., Pauly, J. M., & Hargreaves, B. A. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21967 · Cited by 392
High‐field magnetic resonance imaging of brain iron: birth of a biomarker?
Schenck, J. F., & Zimmerman, E. A. (2004) · NMR in Biomedicine · doi:10.1002/nbm.922 · Cited by 337
Metadata
- Authors
- Yang, Q. X., Williams, G. D., Demeure, R. J., Mosher, T. J., & Smith, M. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-03
- Volume
- 39
- Issue
- 3
- Pages
- 402-409
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2074332790
- Cited by
- 126
- References
- 1
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Removal of local field gradient artifacts in T2*‐weighted images at high fields by gradient‐echo slice excitation profile imaging. https://app.cochat.ai/papers/10.1002/mrm.1910390310
- The paper
- Yang, Q. X., Williams, G. D., Demeure, R. J., Mosher, T. J., & Smith, M. B. (1998). Removal of local field gradient artifacts in T2*‐weighted images at high fields by gradient‐echo slice excitation profile imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.1910390310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.