The DOI matches its Crossref record.
Relaxation anisotropy in cartilage by NMR microscopy (μMRI) at 14‐μm resolution
Abstract
To study the structural anisotropy and the magic‐angle effect in articular cartilage,T1, and T2 images were constructed at a series of orientations of cartilage specimens in the magnetic field by using NMR microscopy (μMRI). An isotropic T 1, and a strong anisotropic T 2 were observed across the cartilage tissue thickness. Three distinct regions in the microscopic MR images corresponded approximately to the superficial, transitional, and radial histological zones in the cartilage. The percentage decrease of T2 follows the pattern of the curve of (3cos 2 θ − 1)2 at the radial zone, where the collagen fibrils are perpendicular to the articular surface. In contrast, little orientational dependence of T 2 was observed at the transitional zone, where the collagen fibrils are more randomly oriented. The result suggests that the interactions between water molecules and proteoglycans have a directional nature, which is somehow influenced by collagen fibril orientation. Hence, T 2 anisotropy could serve as a sensitive and noninvasive marker for molecular‐level orientations in articular cartilage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nondestructive imaging of human cartilage glycosaminoglycan concentration by MRI
Bashir, A., Gray, M. L., Hartke, J., & Burstein, D. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199905)41:5<857::aid-mrm1>3.0.co;2-e · Cited by 571
In vivo T1ρ and T2 mapping of articular cartilage in osteoarthritis of the knee using 3 T MRI
Li, X., Benjamin Ma, C., Link, T. M., Castillo, D.-D., Blumenkrantz, G., Lozano, J., Carballido-Gamio, J., Ries, M., & Majumdar, S. (2007) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2007.01.011 · Cited by 485
Blümich, B., Perlo, J., & Casanova, F. (2008) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2007.10.002 · Cited by 469
Nieminen, M. T., Rieppo, J., Töyräs, J., Hakumäki, J. M., Silvennoinen, J., Hyttinen, M. M., Helminen, H. J., & Jurvelin, J. S. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1218 · Cited by 464
Proteoglycan‐induced changes in T1ρ‐relaxation of articular cartilage at 4T
Akella, S. V. S., Reddy Regatte, R., Gougoutas, A. J., Borthakur, A., Shapiro, E. M., Kneeland, J. B., Leigh, J. S., & Reddy, R. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1208 · Cited by 381
T1ρ relaxation mapping in human osteoarthritis (OA) cartilage: Comparison of T1ρ with T2
Regatte, R. R., Akella, S. V. S., Lonner, J. H., Kneeland, J. B., & Reddy, R. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20536 · Cited by 332
Magic-Angle Effect in Magnetic Resonance Imaging of Articular Cartilage: A Review
XIA, Y. (2000) · Investigative Radiology · doi:10.1097/00004424-200010000-00007 · Cited by 300
Self-citationSodium and T1ρ MRI for molecular and diagnostic imaging of articular cartilage
Borthakur, A., Mellon, E., Niyogi, S., Witschey, W., Kneeland, J. B., & Reddy, R. (2006) · NMR in Biomedicine · doi:10.1002/nbm.1102 · Cited by 266
Xia, Y., Moody, J. B., Burton-Wurster, N., & Lust, G. (2001) · Osteoarthritis and Cartilage · doi:10.1053/joca.2000.0405 · Cited by 266
Self-citationLüssea, S., Claassen, H., Gehrke, T., Hassenpflug, J., Schünke, M., Heller, M., & Glüer, C.-C. (2000) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00144-7 · Cited by 252
Wang, N., Badar, F., & Xia, Y. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26973 · Cited by 18
Self-citation
Metadata
- Authors
- Xia, Y.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 1998-06
- Volume
- 39
- Issue
- 6
- Pages
- 941-949
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2070161476
- Cited by
- 248
- References
- 0
- FWCI
- 6.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.