Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 332

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

T1ρ relaxation mapping in human osteoarthritis (OA) cartilage: Comparison of T1ρ with T2

Open access
Regatte, Ravinder R., Akella, Sarma V.S., Lonner, J.H., Kneeland, J.B., Reddy, Ravinder·2006·Journal of Magnetic Resonance Imaging

Abstract

Purpose: To quantify the spin‐lattice relaxation time in the rotating frame (T 1ρ) in various clinical grades of human osteoarthritis (OA) cartilage specimens obtained from total knee replacement surgery, and to correlate the T 1ρ with OA disease progression and compare it with the transverse relaxation time (T 2). Materials and Methods: Human cartilage specimens were obtained from consenting patients (N = 8) who underwent total replacement of the knee joint at the Pennsylvania Hospital, Philadelphia, PA, USA. T 2‐ and T 1ρ‐weighted images were obtained on a 4.0 Tesla whole‐body GE Signa scanner (GEMS, Milwaukee, WI, USA). A 7‐cm diameter transmit/receive quadrature birdcage coil tuned to 170 MHz was employed. Results: All of the surgical knee replacement OA cartilage specimens showed elevated relaxation times (T 2 and T 1ρ) compared to healthy cartilage tissue. In various grades of OA specimens, the T 1ρ relaxation times varied from 62 ± 5 msec to 100 ± 8 msec (mean ± SEM) depending on the degree of cartilage degeneration. However, T 2 relaxation times varied only from 32 ± 2 msec to 45 ± 4 msec (mean ± SEM) on the same cartilage specimens. The increase in T 2 and T 1ρ in various clinical grades of OA specimens were ∼5–50% and 30–120%, respectively, compared to healthy specimens. The degenerative status of the cartilage specimens was also confirmed by histological evaluation. Conclusion: Preliminary results from a limited number of knee specimens (N = 8) suggest that T 1ρ relaxation mapping is a sensitive noninvasive marker for quantitatively predicting and monitoring the status of macromolecules in early OA. Furthermore, T 1ρ has a higher dynamic range (>100%) for detecting early pathology compared to T 2. This higher dynamic range can be exploited to measure even small macromolecular changes with greater accuracy compared to T 2. Because of these advantages, T 1ρ relaxation mapping may be useful for evaluating early OA therapy. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.20536

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 332

Metadata

Authors
Regatte, R. R., Akella, S. V. S., Lonner, J. H., Kneeland, J. B., & Reddy, R.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2006-03-07
Volume
23
Issue
4
Pages
547-553
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2101235028
Cited by
332
References
18
FWCI
6.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: T1ρ relaxation mapping in human osteoarthritis (OA) cartilage: Comparison of T1ρ with T2. https://app.cochat.ai/papers/10.1002/jmri.20536
The paper
Regatte, R. R., Akella, S. V. S., Lonner, J. H., Kneeland, J. B., & Reddy, R. (2006). T1ρ relaxation mapping in human osteoarthritis (OA) cartilage: Comparison of T1ρ with T2. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20536

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.