The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement of brain glutamate using TE‐averaged PRESS at 3T
Open accessAbstract
A method is introduced that provides improved in vivo spectroscopic measurements of glutamate (Glu), glutamine (Gln), choline (Cho), creatine (Cre), N‐acetyl compounds (NA tot, NAA + NAAG), and the inositols (mI and sI). It was found that at 3T, TE averaging, the f1 = 0 slice of a 2D J‐resolved spectrum, yielded unobstructed signals for Glu, Glu + Gln (Glx), mI, NA tot, Cre, and Cho. The C4 protons of Glu at 2.35 ppm, and the C2 protons of Glx at 3.75 ppm were well resolved and yielded reliable measures of Glu/Gln stasis. Apparent T1/T2 values were obtained from the raw data, and metabolite tissue levels were determined relative to a readily available standard. A repeatibility error of <5%, and a coefficient of variation (CV) of <10% were observed for brain Glu levels in a study of six normal volunteers. Magn Reson Med 51:435–440, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Role of Excitotoxicity in Neurodegenerative Disease
Doble, A. (1999) · Pharmacology & Therapeutics · doi:10.1016/s0163-7258(98)00042-4 · Cited by 723
Cited by
Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA
Mullins, P. G., McGonigle, D. J., O'Gorman, R. L., Puts, N. A. J., Vidyasagar, R., Evans, C. J., & Edden, R. A. E. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2012.12.004 · Cited by 553
Evidence of elevated glutamate in multiple sclerosis using magnetic resonance spectroscopy at 3 T
Srinivasan, R., Sailasuta, N., Hurd, R., Nelson, S., & Pelletier, D. (2005) · Brain · doi:10.1093/brain/awh467 · Cited by 465
Self-citationElevated insular glutamate in fibromyalgia is associated with experimental pain
Harris, R. E., Sundgren, P. C., Craig, A. D., Kirshenbaum, E., Sen, A., Napadow, V., & Clauw, D. J. (2009) · Arthritis & Rheumatism · doi:10.1002/art.24849 · Cited by 328
Mao, X. (2012) · Archives of General Psychiatry · doi:10.1001/archgenpsychiatry.2011.1519 · Cited by 296
Glutamate and glutamine: a review of in vivo MRS in the human brain
Ramadan, S., Lin, A., & Stanwell, P. (2013) · NMR in Biomedicine · doi:10.1002/nbm.3045 · Cited by 282
Metadata
- Authors
- Hurd, R., Sailasuta, N., Srinivasan, R., Vigneron, D. B., Pelletier, D., & Nelson, S. J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-02-25
- Volume
- 51
- Issue
- 3
- Pages
- 435-440
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2007428718
- Cited by
- 238
- References
- 1
- FWCI
- 10.69
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of brain glutamate using TE‐averaged PRESS at 3T. https://app.cochat.ai/papers/10.1002/mrm.20007
- The paper
- Hurd, R., Sailasuta, N., Srinivasan, R., Vigneron, D. B., Pelletier, D., & Nelson, S. J. (2004). Measurement of brain glutamate using TE‐averaged PRESS at 3T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.