In vivo assessment of tumoral angiogenesis
The DOI matches its Crossref record.
Abstract
Vessel size imaging (VSI) for brain tumor characterization was evaluated and the vessel size index measured by MRI (VSI MRI) was correlated with VSI obtained by histology (VSI histo). Blood volume (BV) and VSI maps were obtained on 12 rats by simultaneous measurements of R 2* and R 2, before and after the injection of a macromolecular contrast agent, AMI‐227. Immunostaining of collagen IV in vessels was performed. An expression was derived for evaluating VSI from stereologic measurements on histology data (VSI histo). On BV and VSI images obtained from large‐size tumors (n = 9), three regions could be distinguished and correlated well with histological sections: a high BV region surrounding the tumor, a necrotic area where BV is very low, and a viable tumor tissue region showing lower BV but higher VSI than the normal rat cortex, with the presence of larger vessels. The quantitative analysis showed a good correlation (Spearman rank's rho = 0.74) between VSI histo and VSI MRI with a linear regression coefficient of 1.17. The good correlation coefficient supports VSI imaging as a quantitative method for tumor vasculature characterization. Magn Reson Med 51:533–541, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Patient-derived organoids model treatment response of metastatic gastrointestinal cancers
Vlachogiannis, G., Hedayat, S., Vatsiou, A., Jamin, Y., Fernández-Mateos, J., Khan, K., Lampis, A., Eason, K., Huntingford, I., Burke, R., et al. (2018) · Science · doi:10.1126/science.aao2774 · Cited by 2,096
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Zhao, F., Wang, P., Hendrich, K., Ugurbil, K., & Kim, S.-G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.11.013 · Cited by 266
Clinical applications of iron oxide nanoparticles for magnetic resonance imaging of brain tumors
Iv, M., Telischak, N., Feng, D., Holdsworth, S. J., Yeom, K. W., & Daldrup-Link, H. E. (2015) · Nanomedicine · doi:10.2217/nnm.14.203 · Cited by 134
Neurovascular abnormalities in humans and mice with Huntington's disease
Lin, C.-Y., Hsu, Y.-H., Lin, M.-H., Yang, T.-H., Chen, H.-M., Chen, Y.-C., Hsiao, H.-Y., Chen, C.-C., Chern, Y., & Chang, C. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2013.08.019 · Cited by 98
Metadata
- Authors
- Troprès, I., Lamalle, L., Péoc'h, M., Farion, R., Usson, Y., Décorps, M., & Rémy, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-02-25
- Volume
- 51
- Issue
- 3
- Pages
- 533-541
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2111620238
- Cited by
- 126
- References
- 0
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo assessment of tumoral angiogenesis. https://app.cochat.ai/papers/10.1002/mrm.20017
- The paper
- Troprès, I., Lamalle, L., Péoc'h, M., Farion, R., Usson, Y., Décorps, M., & Rémy, C. (2004). In vivo assessment of tumoral angiogenesis. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.