The DOI matches its Crossref record.
Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithm
Open accessAbstract
A two‐point Dixon technique using a novel phase‐correction algorithm and commercially available dual‐echo fast gradient‐echo pulse sequence is presented. The phase‐correction algorithm determines the directional rather than phase distribution of signals due to field inhomogeneities. Specifically, a region‐growing scheme uses precalculated spatial gradients of the signal phase to guide the growth sequence, so there is no need to manually select the seeds or use an empirical angular threshold. Further, the determination of the signal direction of a given pixel is based on both the amplitude and phase of the surrounding pixels, the direction of which has already been determined. The advantages of this algorithm include its easy implementation, computational efficiency, and robustness in the presence of pixels with large phase uncertainty. The feasibility and usefulness of the technique are demonstrated in vivo with artifact‐free water and fat images of an entire abdomen in a single breath‐hold. Magn Reson Med 52:415–419, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Dual‐echo Dixon imaging with flexible choice of echo times
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22578 · Cited by 320
Liver Fat Quantification by Dual-echo MR Imaging Outperforms Traditional Histopathological Analysis
Fischer, M. A., Raptis, D. A., Montani, M., Graf, R., Clavien, P.-A., Nanz, D., Alkadhi, H., & Scheffel, H. (2012) · Academic Radiology · doi:10.1016/j.acra.2012.05.009 · Cited by 25
Metadata
- Authors
- Ma, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-07-23
- Volume
- 52
- Issue
- 2
- Pages
- 415-419
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1998872152
- Cited by
- 249
- References
- 0
- FWCI
- 5.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithm. https://app.cochat.ai/papers/10.1002/mrm.20146
- The paper
- Ma, J. (2004). Breath‐hold water and fat imaging using a dual‐echo two‐point dixon technique with an efficient and robust phase‐correction algorithm. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20146
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.