The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Dual‐echo Dixon imaging with flexible choice of echo times
Open accessAbstract
In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Fast, automated, N‐dimensional phase‐unwrapping algorithm
Jenkinson, M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10354 · Cited by 695
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Dixon techniques for water and fat imaging
Ma, J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21492 · Cited by 610
Multicoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
MR imaging: clinical use of the inversion recovery sequence.
Bydder, G. M., & YOUNG, I. R. (1985) · PubMed · Cited by 477
MR Imaging: Clinical Use of the Inversion Recovery Sequence
Bydder, G. M., & Young, I. R. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198507010-00002 · Cited by 426
Multipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Cited by
Maspero, M., Savenije, M. H. F., Dinkla, A. M., Seevinck, P. R., Intven, M. P. W., Jurgenliemk-Schulz, I. M., Kerkmeijer, L. G. W., & van den Berg, C. A. T. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aada6d · Cited by 253
Rubinow, K. B., Wang, S., den Hartigh, L. J., Subramanian, S., Morton, G. J., Buaas, F. W., Lamont, D., Gray, N., Braun, R. E., & Page, S. T. (2015) · Andrology · doi:10.1111/andr.12055 · Cited by 16
Metadata
- Authors
- Eggers, H., Brendel, B., Duijndam, A., & Herigault, G.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-09-21
- Volume
- 65
- Issue
- 1
- Pages
- 96-107
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2080056320
- Cited by
- 320
- References
- 15
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dual‐echo Dixon imaging with flexible choice of echo times. https://app.cochat.ai/papers/10.1002/mrm.22578
- The paper
- Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011). Dual‐echo Dixon imaging with flexible choice of echo times. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22578
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.