Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 320

The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.

Dual‐echo Dixon imaging with flexible choice of echo times

Open access
Eggers, Holger, Brendel, Bernhard, Duijndam, Adri, Herigault, Gwenael·2011·Magnetic Resonance in Medicine

Abstract

In this work, a new two‐point method for water–fat imaging is described and explored. It generalizes existing two‐point methods by eliminating some of the restrictions that these methods impose on the choice of echo times. Thus, the new two‐point method promises to provide more freedom in the selection of protocol parameters and to reach higher scan efficiency. Its performance was studied theoretically and was evaluated experimentally in abdominal imaging with a multigradient‐echo sequence. While depending on the choice of echo times, it is generally found to be favorable compared to existing two‐point methods. Notably, water images with higher spatial resolution and better signal‐to‐noise ratio were attained with it in single breathholds at 3.0 T and 1.5 T, respectively. The use of more accurate spectral models of fat is shown to substantially reduce observed variations in the extent of fat suppression. The acquisition of in‐ and opposed‐phase images is demonstrated to be replaceable by a synthesis from water and fat images. The new two‐point method is finally also applied to autocalibrate a multidimensional eddy current correction and to enhance the fat suppression achieved with three‐point methods in this way, especially toward the edges of larger field of views. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22578

Cites

15 of 15 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 15 references

Cited by

See all 320

Metadata

Authors
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2010-09-21
Volume
65
Issue
1
Pages
96-107
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2080056320
Cited by
320
References
15
FWCI
8.20
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual‐echo Dixon imaging with flexible choice of echo times. https://app.cochat.ai/papers/10.1002/mrm.22578
The paper
Eggers, H., Brendel, B., Duijndam, A., & Herigault, G. (2011). Dual‐echo Dixon imaging with flexible choice of echo times. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22578

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.