The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Analysis of noise effects on DTI‐based tractography using the brute‐force and multi‐ROI approach
Abstract
Diffusion tensor tractography based on line propagation is a promising and widely used technique, but it is known to be sensitive to noise and the size and location of the seed regions of interest (ROIs). The effects of these parameters on the tractography results were analyzed quantitatively using high‐resolution diffusion tensor imaging (DTI) with a high signal‐to‐noise ratio (SNR) on a fixed mouse brain. The anterior commissure (AC), as judged from a T2‐weighted image, was used as an anatomical reference within which the tracts could be located. Monte Carlo simulation was performed by adding Gaussian noise to the time domain data and repeating the tractography. Deviations of the tracking results were measured as a function of SNR. Such noise effects were evaluated for a simple one‐ROI approach and a combined two‐ROI and brute‐force (BF) approach. The influence of ROI size and location for the two‐ROI + BF approach was also analyzed. The results confirmed the hypothesis that one can increase the validity of DTI‐based tractography by adopting the BF and multi‐ROI approach, with respect to the simple one‐ROI approach. Magn Reson Med 52:559–565, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Spatial transformations of diffusion tensor magnetic resonance images
Alexander, D. C., Pierpaoli, C., Basser, P. J., & Gee, J. C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.963816 · Cited by 610 · cited 1×
“Probabilistic studies, in which results from many individuals are averaged, may ameliorate this shortcoming but they may not be suitable for single-subject studies, such as those required for clinical diagnoses (23,25–28).”
BackgroundDiffusion Tensor Imaging and Axonal Tracking in the Human Brainstem
Stieltjes, B., Kaufmann, W. E., van Zijl, P. C. M., Fredericksen, K., Pearlson, G. D., Solaiyappan, M., & Mori, S. (2001) · NeuroImage · doi:10.1006/nimg.2001.0861 · Cited by 492
Self-citation
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Reproducibility of quantitative tractography methods applied to cerebral white matter
Wakana, S., Caprihan, A., Panzenboeck, M. M., Fallon, J. H., Perry, M., Gollub, R. L., Hua, K., Zhang, J., Jiang, H., Dubey, P., et al. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.049 · Cited by 1,686
Self-citationHua, K., Zhang, J., Wakana, S., Jiang, H., Li, X., Reich, D. S., Calabresi, P. A., Pekar, J. J., van Zijl, P. C. M., & Mori, S. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.053 · Cited by 1,514
Self-citationDiffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Self-citationOishi, K., Zilles, K., Amunts, K., Faria, A., Jiang, H., Li, X., Akhter, K., Hua, K., Woods, R., Toga, A. W., et al. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.07.009 · Cited by 568
Self-citation
Metadata
- Authors
- Huang, H., Zhang, J., van Zijl, P. C. M., & Mori, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-08-23
- Volume
- 52
- Issue
- 3
- Pages
- 559-565
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2048897033
- Cited by
- 193
- References
- 4
- FWCI
- 6.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.