The DOI matches its Crossref record.
Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series
Open accessAbstract
The purpose of this study was to quantify microcirculation and microvasculature in breast lesions by pharmacokinetic analysis of Gd‐DTPA‐enhanced MRI series. Strongly T1‐weighted MR images were acquired in 18 patients with breast lesions using a saturation‐recovery‐TurboFLASH sequence. Concentration‐time courses were determined for blood, pectoral muscle, and breast masses and subsequently analyzed by a two‐compartment model to estimate plasma flow and the capillary transfer coefficient per unit of plasma volume (F/VP,KPS/VP) as well as fractional volumes of the plasma and interstitial space (fP,fI). Tissue parameters determined for pectoral muscle (fP= 0.04 ± 0.01,fI= 0.09 ± 0.01,F/VP= 2.4 ± 1.3 min‐1, and KPS/VP= 1.2 ± 0.5 min‐1) and 10 histologically proven carcinomas (fP= 0.20 ± 0.07,fI= 0.34 ± 0.16,F/VP= 2.4 ± 0.7 min‐1, and KPS/VP= 0.86 ± 0.62 min‐1) agreed reasonable well with literature data. Best separation between malignant and benign lesions was obtained by the ratio KPS/F(0.35 ± 0.17 vs. 1.23 ± 0.65). The functional imaging technique presented appears promising to quantitatively characterize tumor pathophysiology. Its impact on diagnosis and therapy management of breast tumors, however, has to be evaluated in larger patient studies. Magn Reson Med 52:420–429, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Giger, M. L., Chan, H., & Boone, J. (2008) · Medical Physics · doi:10.1118/1.3013555 · Cited by 311
Sourbron, S., Ingrisch, M., Siefert, A., Reiser, M., & Herrmann, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22005 · Cited by 276
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Cramer, S. P., & Larsson, H. B. (2014) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2014.126 · Cited by 117
Metadata
- Authors
- Brix, G., Kiessling, F., Lucht, R., Darai, S., Wasser, K., Delorme, S., & Griebel, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-07-23
- Volume
- 52
- Issue
- 2
- Pages
- 420-429
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2001974555
- Cited by
- 252
- References
- 0
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series. https://app.cochat.ai/papers/10.1002/mrm.20161
- The paper
- Brix, G., Kiessling, F., Lucht, R., Darai, S., Wasser, K., Delorme, S., & Griebel, J. (2004). Microcirculation and microvasculature in breast tumors: Pharmacokinetic analysis of dynamic MR image series. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20161
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.