The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly resolved in vivo 1H NMR spectroscopy of the mouse brain at 9.4 T
Open accessAbstract
An efficient shim system and an optimized localization sequence were used to measure in vivo 1 H NMR spectra from cerebral cortex, hippocampus, striatum, and cerebellum of C57BL/6 mice at 9.4 T. The combination of automatic first‐ and second‐order shimming (FASTMAP) with strong custom‐designed second‐order shim coils (shim strength up to 0.04 mT/cm 2) was crucial to achieve high spectral resolution (water line width of 11–14 Hz). Requirements for second‐order shim strengths to compensate field inhomogeneities in the mouse brain at 9.4 T were assessed. The achieved spectral quality (resolution, S/N, water suppression, localization performance) allowed reliable quantification of 16 brain metabolites (LCModel analysis) from 5–10‐μL brain volumes. Significant regional differences (up to 2‐fold, P < 0.05) were found for all quantified metabolites but Asp, Glc, and Gln. In contrast, 1 H NMR spectra measured from the striatum of C57BL/6, CBA, and CBA/BL6 mice revealed only small (<13%, P < 0.05) interstrain differences in Gln, Glu, Ins, Lac, NAAG, and PE. It is concluded that 1 H NMR spectroscopy at 9.4 T can provide precise biochemical information from distinct regions of the mouse brain noninvasively that can be used for monitoring of disease progression and treatment as well as phenotyping in transgenic mice models. Magn Reson Med 52:478–484, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Andreassen, O. A., Dedeoglu, A., Ferrante, R. J., Jenkins, B. G., Ferrante, K. L., Thomas, M., Friedlich, A., Browne, S. E., Schilling, G., Borchelt, D. R., et al. (2001) · Neurobiology of Disease · doi:10.1006/nbdi.2001.0406 · Cited by 293
Cited by
Metabolomics: Current analytical platforms and methodologies
(2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2004.11.021 · Cited by 1,192
Simultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981
Tkáč, I., Öz, G., Adriany, G., Uğurbil, K., & Gruetter, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22086 · Cited by 364
Self-citationRoss, J. M., Öberg, J., Brené, S., Coppotelli, G., Terzioglu, M., Pernold, K., Goiny, M., Sitnikov, R., Kehr, J., Trifunovic, A., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1008189107 · Cited by 299
Janik, R., Thomason, L. A. M., Stanisz, A. M., Forsythe, P., Bienenstock, J., & Stanisz, G. J. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.018 · Cited by 283
Metadata
- Authors
- Tkáč, I., Henry, P., Andersen, P., Keene, C. D., Low, W. C., & Gruetter, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-08-23
- Volume
- 52
- Issue
- 3
- Pages
- 478-484
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2098148413
- Cited by
- 187
- References
- 1
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly resolved in vivo 1H NMR spectroscopy of the mouse brain at 9.4 T. https://app.cochat.ai/papers/10.1002/mrm.20184
- The paper
- Tkáč, I., Henry, P., Andersen, P., Keene, C. D., Low, W. C., & Gruetter, R. (2004). Highly resolved in vivo 1H NMR spectroscopy of the mouse brain at 9.4 T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20184
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.