The DOI matches its Crossref record.
Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scaling
Abstract
In this work, the dependence of parallel MRI performance on main magnetic field strength is experimentally investigated. Using the general framework of electrodynamic scaling, the B0‐dependent behavior of the relevant radiofrequency fields at a single physical field strength of 7 T is studied. In the chosen implementation this is accomplished by adjusting the permittivity and conductivity of a homogeneous spherical phantom. With different mixing ratios of decane, ethanol, purified water, N‐methylformamide, and sodium chloride, field strengths in the range of 1.5 to 11.5 T are mimicked. Based on sensitivity maps of an eight‐coil receiver array, the field‐dependent performance of parallel imaging is assessed in terms of the geometry factor g, which reflects noise enhancement in parallel imaging reconstruction. At low field strengths the SNR penalty was nearly independent of B0 and favorably low for 1D reduction factors up to between 3 and 4. At higher field strengths the transition between favorable and prohibitive parallel imaging conditions was found to shift toward higher feasible reduction factors. These findings are in good agreement with previous theoretical predictions. From this agreement it is concluded that parallel MRI at high B0 benefits specifically from onsetting far‐field behavior of the involved radiofrequency fields. Magn Reson Med 52:953–964, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moeller, S., Yacoub, E., Olman, C. A., Auerbach, E., Strupp, J., Harel, N., & Uğurbil, K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22361 · Cited by 1,586
Self-citationMultiplexed echo planar imaging for sub-second whole brain FMRI and fast diffusion imaging
Feinberg, D. A., Moeller, S., Smith, S. M., Auerbach, E., Ramanna, S., Glasser, M. F., Miller, K. L., Ugurbil, K., & Yacoub, E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015710 · Cited by 1,296
Uğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812
Self-citationDiffusion Tensor MR Imaging and Fiber Tractography: Theoretic Underpinnings
Mukherjee, P., Berman, J. I., Chung, S. W., Hess, C. P., & Henry, R. G. (2008) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1051 · Cited by 521
B1 destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil
Van de Moortele, P., Akgun, C., Adriany, G., Moeller, S., Ritter, J., Collins, C. M., Smith, M. B., Vaughan, J. T., & Uğurbil, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20708 · Cited by 468
Self-citation
Metadata
- Authors
- Wiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-10-26
- Volume
- 52
- Issue
- 5
- Pages
- 953-964
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1981899568
- Cited by
- 198
- References
- 0
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scaling. https://app.cochat.ai/papers/10.1002/mrm.20281
- The paper
- Wiesinger, F., Van de Moortele, P., Adriany, G., De Zanche, N., Ugurbil, K., & Pruessmann, K. P. (2004). Parallel imaging performance as a function of field strength—An experimental investigation using electrodynamic scaling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20281
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.