The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Quantitative “magnetic resonance immunohistochemistry” with ligand‐targeted 19F nanoparticles
Open accessAbstract
Unstable atherosclerotic plaques exhibit microdeposits of fibrin that may indicate the potential for a future rupture. However, current methods for evaluating the stage of an atherosclerotic lesion only involve characterizing the level of vessel stenosis, without delineating which lesions are beginning to rupture. Previous work has shown that fibrin‐targeted, liquid perfluorocarbon nanoparticles, which carry a high payload of gadolinium, have a high sensitivity and specificity for detecting fibrin with clinical 1 H MRI. In this work, the perfluorocarbon content of the targeted nanoparticles is exploited for the purposes of 19 F imaging and spectroscopy to demonstrate a method for quantifiable molecular imaging of fibrin in vitro at 4.7 T. Additionally, the quantity of bound nanoparticles formulated with different perfluorocarbon species was calculated using spectroscopy. Results indicate that the high degree of nanoparticle binding to fibrin clots and the lack of background 19 F signal allow accurate quantification using spectroscopy at 4.7 T, as corroborated with proton relaxation rate measurements at 1.5 T and trace element (gadolinium) analysis. Finally, the extension of these techniques to a clinically relevant application, the evaluation of the fibrin burden within an ex vivo human carotid endarterectomy sample, demonstrates the potential use of these particles for uniquely identifying unstable atherosclerotic lesions in vivo. Magn Reson Med 52:1255–1262, 2004. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093185.16083.95 · Cited by 696
Self-citationFlacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
Self-citation
Cited by
19F Magnetic Resonance Imaging (MRI): From Design of Materials to Clinical Applications
Tirotta, I., Dichiarante, V., Pigliacelli, C., Cavallo, G., Terraneo, G., Bombelli, F. B., Metrangolo, P., & Resnati, G. (2015) · Chemical Reviews · doi:10.1021/cr500286d · Cited by 521
Advanced functional materials based on polyhedral oligomeric silsesquioxane (POSS)
Tanaka, K., & Chujo, Y. (2012) · J. Mater. Chem. · doi:10.1039/c1jm14231c · Cited by 489
Nanotechnological applications in medicine
Caruthers, S. D., Wickline, S. A., & Lanza, G. M. (2007) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2007.01.006 · Cited by 441
Self-citationBibee, K. P., Cheng, Y., Ching, J. K., Marsh, J. N., Li, A. J., Keeling, R. M., Connolly, A. M., Golumbek, P. T., Myerson, J. W., Hu, G., et al. (2014) · The FASEB Journal · doi:10.1096/fj.13-237388 · Cited by 83
Self-citation
Metadata
- Authors
- Morawski, A. M., Winter, P. M., Yu, X., Fuhrhop, R. W., Scott, M. J., Hockett, F., Robertson, J. D., Gaffney, P. J., Lanza, G. M., & Wickline, S. A.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2004-11-23
- Volume
- 52
- Issue
- 6
- Pages
- 1255-1262
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2086673370
- Cited by
- 192
- References
- 2
- FWCI
- 9.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative “magnetic resonance immunohistochemistry” with ligand‐targeted 19F nanoparticles. https://app.cochat.ai/papers/10.1002/mrm.20287
- The paper
- Morawski, A. M., Winter, P. M., Yu, X., Fuhrhop, R. W., Scott, M. J., Hockett, F., Robertson, J. D., Gaffney, P. J., Lanza, G. M., & Wickline, S. A. (2004). Quantitative “magnetic resonance immunohistochemistry” with ligand‐targeted 19F nanoparticles. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20287
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.