Mitigation of susceptibility‐induced signal loss in neuroimaging using localized shim coils
Open accessThe DOI matches its Crossref record.
Abstract
Correction of magnetic field distortions is essential for obtaining accurate brain blood‐oxygen‐level‐dependent functional magnetic resonance imaging (fMRI) activation maps. The present work introduces an active shimming method that utilizes the magnetic field generated by resistive shim coils placed in the mouth to locally homogenize the magnetic field in the inferior portion of the frontal lobe, where the field is most seriously distorted. The shimming field can be optimized in situ patient by patient for the region of interest of the scanner operator's choice. The method at 1.5 T is shown to be effective in reducing field inhomogeneity and in recovery of fMRI signal. For example, in a region of interest approximately of 149 cm 3, a coil of simple geometry can reduce the root mean square of the magnetic field by more than 50% and the recovered signal increases the extent of activation detected in a breath‐holding fMRI experiment. Magn Reson Med 53:243–248, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Overview of Functional Magnetic Resonance Imaging
Glover, G. H. (2011) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2010.11.001 · Cited by 1,024
Self-citationWeiskopf, N., Hutton, C., Josephs, O., & Deichmann, R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.029 · Cited by 475
Dynamic multi-coil shimming of the human brain at 7T
Juchem, C., Nixon, T. W., McIntyre, S., Boer, V. O., Rothman, D. L., & de Graaf, R. A. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.07.005 · Cited by 151
Magnetic Field Modeling with a Set of Individual Localized Coils
Juchem, C., Nixon, T. W., McIntyre, S., Rothman, D. L., & Graaf, R. A. D. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.03.008 · Cited by 91
Bellgowan, P. S. F., Bandettini, P. A., van Gelderen, P., Martin, A., & Bodurka, J. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.042 · Cited by 84
“Recently, Wong and Mazaheri (2004) proposed using an external local shim coil to compensate for the field inhomogeneities, and Hsu and Glover (2005) proposed using a resistive shim coils placed in the mouth.”
Background
Metadata
- Authors
- Hsu, J., & Glover, G. H.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-01-27
- Volume
- 53
- Issue
- 2
- Pages
- 243-248
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2043674983
- Cited by
- 95
- References
- 0
- FWCI
- 4.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.