The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
RESTORE: Robust estimation of tensors by outlier rejection
Abstract
Signal variability in diffusion weighted imaging (DWI) is influenced by both thermal noise and spatially and temporally varying artifacts such as subject motion and cardiac pulsation. In this paper, the effects of DWI artifacts on estimated tensor values, such as trace and fractional anisotropy, are analyzed using Monte Carlo simulations. A novel approach for robust diffusion tensor estimation, called RESTORE (for robust estimation of tensors by outlier rejection), is proposed. This method uses iteratively reweighted least‐squares regression to identify potential outliers and subsequently exclude them. Results from both simulated and clinical diffusion data sets indicate that the RESTORE method improves tensor estimation compared to the commonly used linear and nonlinear least‐squares tensor fitting methods and a recently proposed method based on the Geman–McClure M‐estimator. The RESTORE method could potentially remove the need for cardiac gating in DWI acquisitions and should be applicable to other MR imaging techniques that use univariate or multivariate regression to fit MRI data to a model. Magn Reson Med 53:1088–1095, 2005. Published 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Huber, P. J. (1981) · Wiley Series in Probability and Statistics · doi:10.1002/0471725250 · Cited by 7,066
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Self-citationEstimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Data Reduction and Error Analysis for the Physical Sciences.
C., E. L., & Bevington, P. R. (1972) · Journal of the American Statistical Association · doi:10.2307/2284752 · Cited by 3,534
The Influence Curve and its Role in Robust Estimation
Hampel, F. R. (1974) · Journal of the American Statistical Association · doi:10.1080/01621459.1974.10482962 · Cited by 2,706
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Self-citationToward a quantitative assessment of diffusion anisotropy
Pierpaoli, C., & Basser, P. J. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360612 · Cited by 2,405
Self-citationAlternatives to the Median Absolute Deviation
Rousseeuw, P. J., & Croux, C. (1993) · Journal of the American Statistical Association · doi:10.1080/01621459.1993.10476408 · Cited by 1,949
Alternatives to the Median Absolute Deviation
Rousseeuw, P. J., & Croux, C. (1993) · Journal of the American Statistical Association · doi:10.2307/2291267 · Cited by 1,466
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Self-citationMeasurement of signal intensities in the presence of noise in MR images
Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595711 · Cited by 1,017
Jones, D. K. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20033 · Cited by 773
Self-citationRobust regression methods for computer vision: A review
Meer, P., Mintz, D., Rosenfeld, A., & Kim, D. Y. (1991) · International Journal of Computer Vision · doi:10.1007/bf00127126 · Cited by 638
Statistical methods for tomographic image reconstruction
Geman, S., & McClure, D. E. (1987) · Medical Entomology and Zoology · Cited by 579
Comprehensive approach for correction of motion and distortion in diffusion‐weighted MRI
Rohde, G. K., Barnett, A. S., Basser, P. J., Marenco, S., & Pierpaoli, C. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10677 · Cited by 533
Self-citationThe b matrix in diffusion tensor echo‐planar imaging
Mattiello, J., Basser, P. J., & Le Bihan, D. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370226 · Cited by 239
Distortion correction and robust tensor estimation for MR diffusion imaging
Mangin, J.-F., Poupon, C., Clark, C., Le Bihan, D., & Bloch, I. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00079-8 · Cited by 194
Cited by
White matter integrity, fiber count, and other fallacies: The do's and don'ts of diffusion MRI
Jones, D. K., Knösche, T. R., & Turner, R. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.081 · Cited by 2,402
Self-citationRich-club organization of the human connectome
van den Heuvel, M. P., & Sporns, O. (2011) · The Journal of Neuroscience · doi:10.1523/jneurosci.3539-11.2011 · Cited by 2,354
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Dipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
“In addition, there is ongoing research on methods to robustly fit the tensor model, in the face of noisy data (Chang et al., 2005, 2012).”
MethodThe hubs of the human connectome are generally implicated in the anatomy of brain disorders
Crossley, N. A., Mechelli, A., Scott, J., Carletti, F., Fox, P. T., McGuire, P., & Bullmore, E. T. (2014) · Brain · doi:10.1093/brain/awu132 · Cited by 1,166
Metadata
- Authors
- Chang, L., Jones, D. K., & Pierpaoli, C.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-04-20
- Volume
- 53
- Issue
- 5
- Pages
- 1088-1095
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2105034316
- Cited by
- 606
- References
- 18
- FWCI
- 7.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.