Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Magnetic resonance imaging of cardiomyocyte apoptosis with a novel magneto‐optical nanoparticle

Open access
Sosnovik, David E., Schellenberger, Eyk A., Nahrendorf, Matthias, Novikov, Mikhail S., Matsui, Takashi, Dai, George, Reynolds, Fred, Grazette, Luanda, Rosenzweig, Anthony, Weissleder, Ralph, Josephson, Lee · 2005 · Magnetic Resonance in Medicine

Abstract

The ability to image cardiomyocyte apoptosis in vivo with high‐resolution MRI could facilitate the development of novel cardioprotective therapies. The sensitivity of the novel nanoparticle AnxCLIO‐Cy5.5 for cardiomyocyte apoptosis was thus compared in vitro to that of annexin V‐FITC and showed a high degree of colocalization. MRI was then performed, following transient coronary artery (LAD) occlusion, in five mice given AnxCLIO‐Cy5.5 and in four mice given an identical dose (2 mg Fe/kg) of CLIO‐Cy5.5. MR signal intensity and myocardial T2* were evaluated, in vivo, in hypokinetic regions of myocardium in the LAD distribution. Ex vivo fluorescence imaging was performed to confirm the in vivo findings. Myocardial T2* was significantly lower in the mice given AnxCLIO‐Cy5.5 (8.1 versus 13.2 ms, P < 0.01), and fluorescence target to background ratio was significantly higher (2.1 versus 1.1, P < 0.01). This study thus demonstrates the feasibility of obtaining high‐resolution MR images of cardiomyocyte apoptosis in vivo with the novel nanoparticle, AnxCLIO‐Cy5.5. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.20617

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Apoptosis in human acute myocardial infarction.

    Saraste, A., Pulkki, K., Kallajoki, M., Henriksen, K., Parvinen, M., & Voipio-Pulkki, L.-M. (1997) · Circulation · doi:10.1161/01.cir.95.2.320 · Cited by 825 · cited 2×

    “CM apoptosis is thought to play a central role in several disease processes involving the heart including ischemia (1,2), reperfusion injury (3,4), and heart failure (5,6).”
    Background

Show all 1 references

Cited by

See all 236

Metadata

Authors
Sosnovik, D. E., Schellenberger, E. A., Nahrendorf, M., Novikov, M. S., Matsui, T., Dai, G., Reynolds, F., Grazette, L., Rosenzweig, A., Weissleder, R., & Josephson, L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2005-08-05
Volume
54
Issue
3
Pages
718-724
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W1993157780
Cited by
236
References
1
FWCI
15.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetic resonance imaging of cardiomyocyte apoptosis with a novel magneto‐optical nanoparticle. https://app.cochat.ai/papers/10.1002/mrm.20617
The paper
Sosnovik, D. E., Schellenberger, E. A., Nahrendorf, M., Novikov, M. S., Matsui, T., Dai, G., Reynolds, F., Grazette, L., Rosenzweig, A., Weissleder, R., & Josephson, L. (2005). Magnetic resonance imaging of cardiomyocyte apoptosis with a novel magneto‐optical nanoparticle. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20617

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.