The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Measurement of fiber orientation distributions using high angular resolution diffusion imaging
Open accessAbstract
High angular resolution measurements of diffusion are used to estimate the angular distribution and diffusion anisotropy of fibers in a voxel. A simple, axially symmetric model of diffusion in white matter fibers is used to relate diffusion measurements to fiber properties. The new technique is called fiber orientation estimated using continuous axially symmetric tensors (FORECAST). It is tested using both numerical simulation and in vivo measurements. The new method agrees with other methods in voxels containing single fibers, but resolves crossing fibers better, at least at the level of diffusion weighting used in this study (tr(b) = 1480 s/mm 2). The simplifying assumptions of the model are tested by comparison with the “model‐free” q‐ball analysis of in vivo data and the results are shown to be in good agreement. The new method addresses the problem of partial volume averaging in diffusion tensor imaging and provides a basis for more reliable estimates of fiber orientation and fractional anisotropy. Magn Reson Med, 2005. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Greiner, W. (1998) · Theoretical Physics · doi:10.1007/978-1-4612-0587-6 · Cited by 6,657
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Estimation of the Effective Self-Diffusion Tensor from the NMR Spin Echo
Basser, P. J., Mattiello, J., & Lebihan, D. (1994) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1994.1037 · Cited by 3,650
Elementary Theory of Angular Momentum
Rose, M. E., & Feld, B. T. (1957) · Physics Today · doi:10.1063/1.3060162 · Cited by 3,612
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Elementary Theory of Angular Momentum
Pincherle, L. (1958) · Physics Bulletin · doi:10.1088/0031-9112/9/2/013 · Cited by 2,788
Diffusion tensor MR imaging of the human brain
Pierpaoli, C., Jezzard, P., Basser, P. J., Barnett, A., & Di Chiro, G. (1996) · Radiology · doi:10.1148/radiology.201.3.8939209 · Cited by 2,664
Self-diffusion in normal and heavy water in the range 1-45.deg.
Mills, R. (1973) · The Journal of Physical Chemistry · doi:10.1021/j100624a025 · Cited by 1,706
Mathematical Methods for Physicists
(1995) · Elsevier eBooks · doi:10.1016/c2009-1-28537-6 · Cited by 1,255
Cited by
Diffusion tensor imaging of the brain
Alexander, A. L., Lee, J. E., Lazar, M., & Field, A. S. (2007) · Neurotherapeutics · doi:10.1016/j.nurt.2007.05.011 · Cited by 2,747
Tournier, J.-D., Calamante, F., & Connelly, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.02.016 · Cited by 2,188
Dipy, a library for the analysis of diffusion MRI data
Garyfallidis, E., Brett, M., Amirbekian, B., Rokem, A., van der Walt, S., Descoteaux, M., Nimmo-Smith, I., & Contributors, D. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00008 · Cited by 1,371
“This q-ball ODF ψ QBI can be obtained analytically from a SH estimation of the diffusion signal (Anderson, 2005; Hess et al., 2006; Descoteaux et al., 2007): where P l ( j ) is the Legendre polynomial of order l corresponding to coefficient j and the coefficients have been normalized by the S0…”
MethodMRtrix: Diffusion tractography in crossing fiber regions
Tournier, J., Calamante, F., & Connelly, A. (2012) · International Journal of Imaging Systems and Technology · doi:10.1002/ima.22005 · Cited by 1,370
Generalized ${ q}$-Sampling Imaging
Yeh, F.-C., Wedeen, V. J., & Tseng, W.-Y. I. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2045126 · Cited by 1,019
Metadata
- Authors
- Anderson, A. W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2005-09-13
- Volume
- 54
- Issue
- 5
- Pages
- 1194-1206
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2001617943
- Cited by
- 463
- References
- 24
- FWCI
- 13.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of fiber orientation distributions using high angular resolution diffusion imaging. https://app.cochat.ai/papers/10.1002/mrm.20667
- The paper
- Anderson, A. W. (2005). Measurement of fiber orientation distributions using high angular resolution diffusion imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20667
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.