The DOI matches its Crossref record.
Effect of the intracellular localization of a Gd‐based imaging probe on the relaxation enhancement of water protons
Open accessAbstract
Gd‐HPDO3A has been internalized into rat hepatocarcinoma cells in the cytoplasm (by electroporation) or in intracellular vesicles (by pinocytosis), respectively. In the former case, the observed relaxation rates are likely dependent upon the amount of internalized paramagnetic complex, whereas in the latter case the relaxation enhancement is “quenched” to a plateau value (about 3 s−1) when the entrapped amount of Gd‐chelate is higher than 1 × 10 10 Gd/cell. The observed behavior has been accounted in terms of a theoretical treatment based on equations formally derived by Labadie et al. (J Magn Reson B 1994;105:99–102). On this basis, entrapment into intracellular vesicles has been treated as a three‐site water exchange (extracellular/cytoplasm/vesicle compartments), whereas the cell pellets containing the paramagnetic agent spread out in the cytoplasm can be analyzed by a two‐site exchange system. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Kim, T., Momin, E., Choi, J., Yuan, K., Zaidi, H., Kim, J., Park, M., Lee, N., McMahon, M. T., Quinones-Hinojosa, A., et al. (2011) · Journal of the American Chemical Society · doi:10.1021/ja1084095 · Cited by 511
Metadata
- Authors
- Terreno, E., Geninatti Crich, S., Belfiore, S., Biancone, L., Cabella, C., Esposito, G., Manazza, A. D., & Aime, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-01-31
- Volume
- 55
- Issue
- 3
- Pages
- 491-497
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2095929490
- Cited by
- 170
- References
- 0
- FWCI
- 9.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of the intracellular localization of a Gd‐based imaging probe on the relaxation enhancement of water protons. https://app.cochat.ai/papers/10.1002/mrm.20793
- The paper
- Terreno, E., Geninatti Crich, S., Belfiore, S., Biancone, L., Cabella, C., Esposito, G., Manazza, A. D., & Aime, S. (2006). Effect of the intracellular localization of a Gd‐based imaging probe on the relaxation enhancement of water protons. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20793
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.