Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
There is uncertainty regarding the risk posed by magnetic resonance imaging (MRI) examinations to pregnant patients. The most frequently used methods, such as single‐shot fast spin echo (ssFSE), often require operation at the specific absorption rate (SAR) limits imposed by safety guidelines. With the introduction of higher‐field systems, such limits will be even more significant for fetal imaging. An electromagnetic solver based on the time domain finite integration technique (FIT) was used to predict SAR in an anatomically realistic model of a pregnant patient (28 weeks' gestation) associated with the radiofrequency (RF) fields from birdcage body coils typical of 1.5 T and 3 T MRI systems (i.e., operating at approximately 64 and 127 MHz, respectively). The results suggest that 1) the highest local SAR is in the mother, with the fetus being exposed to a peak of approximately 40–60% of that value at 64 MHz, increasing to approximately 50–70% at 127 MHz; 2) compliance with U.S. Food and Drug Administration (FDA) and International Commission on Non‐Ionizing Radiation Protection (ICNIRP) guidelines requires control of SAR values averaged over 1 g or 10 g of tissue, respectively; and 3) compliance with Medical Device Agency (MDA) guidelines requires control of the maximum SAR 10g within the fetus. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative growth and development of human brain
Dobbing, J., & Sands, J. (1973) · Archives of Disease in Childhood · doi:10.1136/adc.48.10.757 · Cited by 1,442
Cited by
Cross-hemispheric functional connectivity in the human fetal brain
Thomason, M. E., Dassanayake, M. T., Shen, S., Katkuri, Y., Alexis, M., Anderson, A. L., Yeo, L., Mody, S., Hernandez-Andrade, E., Hassan, S. S., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3004978 · Cited by 225
Lefèvre, J., Germanaud, D., Dubois, J., Rousseau, F., de Macedo Santos, I., Angleys, H., Mangin, J.-F., Hüppi, P. S., Girard, N., & De Guio, F. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhv123 · Cited by 102
Metadata
- Authors
- Hand, J. W., Li, Y., Thomas, E. L., Rutherford, M. A., & Hajnal, J. V.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-02-28
- Volume
- 55
- Issue
- 4
- Pages
- 883-893
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2063173710
- Cited by
- 169
- References
- 1
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy. https://app.cochat.ai/papers/10.1002/mrm.20824
- The paper
- Hand, J. W., Li, Y., Thomas, E. L., Rutherford, M. A., & Hajnal, J. V. (2006). Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20824
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.