Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
There is uncertainty regarding the risk posed by magnetic resonance imaging (MRI) examinations to pregnant patients. The most frequently used methods, such as single‐shot fast spin echo (ssFSE), often require operation at the specific absorption rate (SAR) limits imposed by safety guidelines. With the introduction of higher‐field systems, such limits will be even more significant for fetal imaging. An electromagnetic solver based on the time domain finite integration technique (FIT) was used to predict SAR in an anatomically realistic model of a pregnant patient (28 weeks' gestation) associated with the radiofrequency (RF) fields from birdcage body coils typical of 1.5 T and 3 T MRI systems (i.e., operating at approximately 64 and 127 MHz, respectively). The results suggest that 1) the highest local SAR is in the mother, with the fetus being exposed to a peak of approximately 40–60% of that value at 64 MHz, increasing to approximately 50–70% at 127 MHz; 2) compliance with U.S. Food and Drug Administration (FDA) and International Commission on Non‐Ionizing Radiation Protection (ICNIRP) guidelines requires control of SAR values averaged over 1 g or 10 g of tissue, respectively; and 3) compliance with Medical Device Agency (MDA) guidelines requires control of the maximum SAR 10g within the fetus. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computational Electrodynamics: The Finite-Difference Time-Domain Method
Taflove, A. (1995) · Cited by 10,626
Computational electrodynamics, the finite-difference time-domain method
Rycroft, M. J. (1996) · Journal of Atmospheric and Terrestrial Physics · doi:10.1016/0021-9169(96)80449-1 · Cited by 9,418 · cited 1×
“As in FDTD algorithms, this timestepping process, commonly referred to as a “leap frog scheme,” is fully explicit and thus avoids problems involved with simultaneous equations and matrix inversion (23,24).”
MethodCompilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Gabriel, C. (1996) · doi:10.21236/ada303903 · Cited by 2,097 · cited 2×
“Tissue dielectric properties were based on the 4-ColeCole analysis reported by Gabriel and Gabriel (27) and calculated online (http://www.”
MethodValentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754 · cited 1×
“The water content of the fetus varies from approximately 95% in early pregnancy to approximately 70% at full term (29).”
BackgroundQuantitative growth and development of human brain
Dobbing, J., & Sands, J. (1973) · Archives of Disease in Childhood · doi:10.1136/adc.48.10.757 · Cited by 1,442 · cited 1×
“The water content of the fetal brain at this age is approximately 95% (30).”
BackgroundNagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774 · cited 1×
“The choice of dielectric properties given to bone tissue in previous numerical studies of electromagnetic dosimetry has varied between cancellous bone (32), cancellous and cortical bone (33), cancellous bone and bone marrow (34), and bone marrow/cancellous bone and cortical bone (35).”
BackgroundTIME DOMAIN ELECTROMAGNETIC FIELD COMPUTATION WITH FINITE DIFFERENCE METHODS
WEILAND, T. (1996) · International Journal of Numerical Modelling: Electronic Networks, Devices and Fields · doi:10.1002/(sici)1099-1204(199607)9:4<295::aid-jnm240>3.0.co;2-8 · Cited by 712 · cited 7×
“This provides a solution to the time-dependent Maxwell’s equations using a time-domain variant of the finite integration technique (FIT) (18,19).”
MethodInfluentialDe Wilde, J. P., Rivers, A. W., & Price, D. L. (2005) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2004.08.010 · Cited by 351 · cited 1×
“Although there is no indication that the use of clinical MR procedures during pregnancy produces adverse effects, the safety of such procedures has not been proven (2,3), and there is currently a significant level of uncertainty regarding the risk posed by MRI examinations to pregnant patients (4).”
BackgroundSchepps, J. L., & Foster, K. R. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/6/012 · Cited by 306 · cited 1×
“The prediction of tissue dielectric properties at ultrahigh and microwave frequencies, and their dependence on water content were previously discussed by Schepps and Foster (28).”
BackgroundDimbylow, P. J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/3/003 · Cited by 284 · cited 1×
“The choice of dielectric properties given to bone tissue in previous numerical studies of electromagnetic dosimetry has varied between cancellous bone (32), cancellous and cortical bone (33), cancellous bone and bone marrow (34), and bone marrow/cancellous bone and cortical bone (35).”
BackgroundCollins, C. M., & Smith, M. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1091 · Cited by 260 · cited 1×
“For example, Collins and Smith (40) studied a head model within an idealized birdcage coil at frequencies of 64–345 MHz.”
BackgroundMEDICAL MAGNETIC RESONANCE (MR) PROCEDURES: PROTECTION OF PATIENTS
(2004) · Health Physics · doi:10.1097/00004032-200408000-00008 · Cited by 243
Fetal MRI: techniques and protocols
Prayer, D., Brugger, P., & Prayer, L. (2004) · Pediatric Radiology · doi:10.1007/s00247-004-1246-0 · Cited by 163 · cited 1×
“MRI is increasingly being used to image both mother and fetus because it provides excellent delineation of the cerebral anatomy (1).”
MethodDielectric properties of brain tissue between 0.01 and 10 GHz
Foster, K. R., Schepps, J. L., Stoy, R. D., & Schwan, H. P. (1979) · Physics in Medicine & Biology · doi:10.1088/0031-9155/24/6/008 · Cited by 162 · cited 1×
“10–15% of this water is in a bound state (31), we adjusted the volume fraction of water in the fetal brain for this effect.”
BackgroundFailure to detect intrauterine growth restriction following in utero exposure to MRI.
Myers, C., Duncan, K. R., Gowland, P. A., Johnson, I. R., & Baker, P. N. (1998) · British Journal of Radiology · doi:10.1259/bjr.71.845.9691901 · Cited by 140 · cited 1×
“5 T system were compared with a control group of 148 pregnant women indicated that EPI did not have a marked effect on intrauterine fetal growth (11).”
ResultMaternal fever and birth outcome: A prospective study
Chambers, C. D., Johnson, K. A., Dick, L. M., Felix, R. J., & Jones, K. L. (1998) · Teratology · doi:10.1002/(sici)1096-9926(199812)58:6<251::aid-tera6>3.0.co;2-l · Cited by 138 · cited 1×
“In humans, neural tube and facial defects have also been found in children whose mothers had undergone prolonged or repeated periods of hyperthermia ( 39°C for 24 hr or longer) during the first trimester of pregnancy (9).”
BackgroundPhysical Properties of Tissues
Hammer, B. E. (1991) · Radiology · doi:10.1148/radiology.181.1.128 · Cited by 129 · cited 1×
“Table 1 Permittivity, Conductivity, and Density Values (36) Used in Segmented Mother/Fetus Models*”
MethodPotential heating effect in the gravid uterus during MR HASTE imaging
Levine, D., Zuo, C., Faro, C. B. D. A., & Chen, Q. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1122 · Cited by 81 · cited 3×
“● Pregnant patients can produce a large filling factor within the magnet bore, particularly in the third trimester, leading to reduced air flow through the bore and around the patient (10).”
BackgroundInfluentialSandrini, L., Vaccari, A., Malacarne, C., Cristoforetti, L., & Pontalti, R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/22/012 · Cited by 50 · cited 1×
“The choice of dielectric properties given to bone tissue in previous numerical studies of electromagnetic dosimetry has varied between cancellous bone (32), cancellous and cortical bone (33), cancellous bone and bone marrow (34), and bone marrow/cancellous bone and cortical bone (35).”
BackgroundKainz, W., Chan, D. D., Casamento, J. P., & Bassen, H. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/15/319 · Cited by 34 · cited 1×
“(16) used a finite difference time domain (FDTD) code involving frequency scaling to calculate induced current densities and SARs due to hand-held metal detectors operating at frequencies between 8 kHz and 2 MHz in a model of a woman in the 34th week of pregnancy.”
BackgroundGraham (1998) · doi:10.1002/(sici)1096-9926(199811)58:5<209::aid-tera8>3.0.co;2-q · cited 2×
“Studies using various animal models have shown that hyperthermia during pregnancy can be associated with resorption of the embryo, expulsion of the fetus at a nonviable stage of gestation, fetal death, central nervous system defects, and cardiovascular malformations (8).”
BackgroundMethod
Cited by
Imaging of Pregnant and Lactating Patients: Part 1, Evidence-Based Review and Recommendations
Wang, P. I., Chong, S. T., Kielar, A. Z., Kelly, A. M., Knoepp, U. D., Mazza, M. B., & Goodsitt, M. M. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.11.7405 · Cited by 245
“Sequences such as SSFSE operate at SAR limits imposed by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) [48].”
Cross-hemispheric functional connectivity in the human fetal brain
Thomason, M. E., Dassanayake, M. T., Shen, S., Katkuri, Y., Alexis, M., Anderson, A. L., Yeo, L., Mody, S., Hernandez-Andrade, E., Hassan, S. S., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3004978 · Cited by 225
Imaging of the Placenta: A Multimodality Pictorial Review
Elsayes, K. M., Trout, A. T., Friedkin, A. M., Liu, P. S., Bude, R. O., Platt, J. F., & Menias, C. O. (2009) · RadioGraphics · doi:10.1148/rg.295085242 · Cited by 222
Lefèvre, J., Germanaud, D., Dubois, J., Rousseau, F., de Macedo Santos, I., Angleys, H., Mangin, J.-F., Hüppi, P. S., Girard, N., & De Guio, F. (2016) · Cerebral Cortex · doi:10.1093/cercor/bhv123 · Cited by 102
Metadata
- Authors
- Hand, J. W., Li, Y., Thomas, E. L., Rutherford, M. A., & Hajnal, J. V.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-02-28
- Volume
- 55
- Issue
- 4
- Pages
- 883-893
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2063173710
- Cited by
- 169
- References
- 21
- FWCI
- 9.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.