Abstract
We studied compartmentally specific characteristics of water diffusion in excised frog sciatic nerve by combining T1 or T2 selective acquisitions with pulse‐gradient spin‐echo (PGSE) diffusion weighting, with the specific objective of characterizing myelin water diffusion. Combining a PGSE with a Carr‐Purcell‐Meiboom‐Gill (CPMG) acquisition provided apparent diffusion coefficients (ADCs) for each of the three T2 components found in nerve, including the short‐lived component believed to be derived from myelin water. Double‐inversion‐recovery (DIR) preparation provided an alternate means of discriminating myelin water, and in combination with PGSE provided somewhat different measures of ADC. The DIR measures yielded myelin water ADCs of 0.37 μm 2/ms (parallel to nerve) and 0.13 μm 2/ms (perpendicular to nerve). These ADC estimates were postulated to be more accurate than those based on T2 discrimination, although the difference between the two findings is not clear. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Cited by
Myelin water imaging of multiple sclerosis at 7 T: Correlations with histopathology
Laule, C., Kozlowski, P., Leung, E., Li, D. K. B., MacKay, A. L., & Moore, G. R. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2007.12.008 · Cited by 379
Is diffusion anisotropy an accurate monitor of myelination?
Mädler, B., Drabycz, S. A., Kolind, S. H., Whittall, K. P., & MacKay, A. L. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.047 · Cited by 227
“Currently, the hypothesis that diffusion anisotropy is related to myelin is mainly supported by investigations on excised neuronal tissue [19–23], postmortem brain [24] or from in vivo animal experiments [25–27] but, so far, only preliminary results from in vivo studies on humans [28–30].”
ResultThe Biological Basis of Diffusion Anisotropy
Beaulieu, C. (2009) · Diffusion MRI · doi:10.1016/b978-0-12-374709-9.00006-7 · Cited by 217
Jones, D. K., Alexander, D. C., Bowtell, R., Cercignani, M., Dell'Acqua, F., McHugh, D. J., Miller, K. L., Palombo, M., Parker, G. J. M., Rudrapatna, U. S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.047 · Cited by 183
“adding inversion recovery (IR) to the DW-CPMG experiment (Andrews et al., 2006).”
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
“As an alternative approach, the idea of suppressing nonmyelin water signals using inversion RF to acquire a myelin water-only signal has been proposed.(25,26,55) This idea is conceptually similar to FLAIR, which suppresses CSF signal and generates tissue-only signal based on the T1 difference between CSF and tissue.”
Method
Metadata
- Authors
- Andrews, T. J., Osborne, M. T., & Does, M. D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-06-09
- Volume
- 56
- Issue
- 2
- Pages
- 381-385
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2046066110
- Cited by
- 44
- References
- 1
- FWCI
- 3.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion of myelin water. https://app.cochat.ai/papers/10.1002/mrm.20945
- The paper
- Andrews, T. J., Osborne, M. T., & Does, M. D. (2006). Diffusion of myelin water. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20945
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.