Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 230

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Real‐time rigid body motion correction and shimming using cloverleaf navigators

Open access
van der Kouwe, André J.W., Benner, Thomas, Dale, Anders M.·2006·Magnetic Resonance in Medicine

Abstract

Subject motion during scanning can greatly reduce MRI image quality and is a major reason for discarding data in both clinical and research scanning. The quality of the high‐resolution structural data used for morphometric analysis is especially compromised by subject movement because high‐resolution scans are of longer duration. A method is presented that measures and corrects rigid body motion and associated first‐order shim changes in real time, using a pulse sequence with embedded cloverleaf navigators and a feedback control mechanism. The procedure requires a 12‐s preliminary mapping scan. A single‐path, 4.2‐ms cloverleaf navigator is inserted every repetition time (TR) after the readout of a 3D fast low‐angle shot (FLASH) sequence, requiring no additional RF pulses and minimally impacting scan duration. Every TR, a rigid body motion estimate is made and a correction is fed back to adjust the gradients and shim offsets. Images are corrected and reconstructed on the scanner computer for immediate access. Correction for between‐scan motion can be accomplished by using the same reference map for each scan repetition. Human and phantom tests demonstrated a consistent improvement in image quality if motion occurred during the acquisition. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21038

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 230

Metadata

Authors
van der Kouwe, A. J. W., Benner, T., & Dale, A. M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2006-10-06
Volume
56
Issue
5
Pages
1019-1032
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2024199909
Cited by
230
References
2
FWCI
3.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.