The DOI matches its Crossref record.
3D radial projection technique with ultrashort echo times for sodium MRI: Clinical applications in human brain and skeletal muscle
Abstract
23 Na MRI has the potential to noninvasively detect sodium (Na) content changes in vivo. The goal of this study was to implement 23 Na MRI in a clinical setting for neurooncological and muscular imaging. Due to the biexponential T2 decay of the tissue Na signal with a short component, which ranges between 0.5–8 ms, the measurement of total Na content requires imaging techniques with echo times (TEs) below 0.5 ms. A 3D radial pulse sequence with a TE of 0.2 ms at a spatial resolution of 4 × 4 × 4 mm 3 was developed that allows the acquisition and presentation of Na images on the scanner. This sequence was evaluated in patients with low‐ and high‐grade gliomas, and higher 23 Na MR signals corresponding to an increased Na content were found in the tumor regions. The contrast‐to‐noise ratio (CNR) between tumor and white matter increased from 0.8 ± 0.2 to 1.3 ± 0.3 with tumor grade. In patients with an identified muscular 23 Na channelopathy (Paramyotonia congenita (PC)), induced muscle weakness led to a signal increase of ∼18% in the 23 Na MR images, which was attributed to intracellular Na+ accumulation in this region. Magn Reson Med 57:74–81, 2007. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sodium MRI using a density‐adapted 3D radial acquisition technique
Nagel, A. M., Laun, F. B., Weber, M., Matthies, C., Semmler, W., & Schad, L. R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22157 · Cited by 287
Self-citationBiomedical applications of sodium MRI in vivo
Madelin, G., & Regatte, R. R. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24168 · Cited by 261
Hammon, M., Grossmann, S., Linz, P., Kopp, C., Dahlmann, A., Garlichs, C., Janka, R., Cavallaro, A., Luft, F. C., Uder, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0141336 · Cited by 93
Metadata
- Authors
- Nielles‐Vallespin, S., Weber, M., Bock, M., Bongers, A., Speier, P., Combs, S. E., Wöhrle, J., Lehmann‐Horn, F., Essig, M., & Schad, L. R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-12-26
- Volume
- 57
- Issue
- 1
- Pages
- 74-81
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2012258756
- Cited by
- 180
- References
- 0
- FWCI
- 3.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D radial projection technique with ultrashort echo times for sodium MRI: Clinical applications in human brain and skeletal muscle. https://app.cochat.ai/papers/10.1002/mrm.21104
- The paper
- Nielles‐Vallespin, S., Weber, M., Bock, M., Bongers, A., Speier, P., Combs, S. E., Wöhrle, J., Lehmann‐Horn, F., Essig, M., & Schad, L. R. (2007). 3D radial projection technique with ultrashort echo times for sodium MRI: Clinical applications in human brain and skeletal muscle. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.