The DOI matches its Crossref record.
Time‐resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging
Open accessAbstract
Exact knowledge of blood flow characteristics in the major cerebral vessels is of great relevance for diagnosing cerebrovascular abnormalities. This involves the assessment of hemodynamically critical areas as well as the derivation of biomechanical parameters such as wall shear stress and pressure gradients. A time‐resolved, 3D phase‐contrast (PC) MRI method using parallel imaging was implemented to measure blood flow in three dimensions at multiple instances over the cardiac cycle. The 4D velocity data obtained from 14 healthy volunteers were used to investigate dynamic blood flow with the use of multiplanar reformatting, 3D streamlines, and 4D particle tracing. In addition, the effects of magnetic field strength, parallel imaging, and temporal resolution on the data were investigated in a comparative evaluation at 1.5T and 3T using three different parallel imaging reduction factors and three different temporal resolutions in eight of the 14 subjects. Studies were consistently performed faster at 3T than at 1.5T because of better parallel imaging performance. A high temporal resolution (65 ms) was required to follow dynamic processes in the intracranial vessels. The 4D flow measurements provided a high degree of vascular conspicuity. Time‐resolved streamline analysis provided features that have not been reported previously for the intracranial vasculature. Magn Reson Med 57:127–140, 2007. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
4D flow cardiovascular magnetic resonance consensus statement
Dyverfeldt, P., Bissell, M., Barker, A. J., Bolger, A. F., Carlhäll, C.-J., Ebbers, T., Francios, C. J., Frydrychowicz, A., Geiger, J., Giese, D., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0174-5 · Cited by 877
Markl, M., Frydrychowicz, A., Kozerke, S., Hope, M., & Wieben, O. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23632 · Cited by 788
Hemodynamics of Cerebral Aneurysms
Sforza, D. M., Putman, C. M., & Cebral, J. R. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102126 · Cited by 466
Markl, M., Kilner, P. J., & Ebbers, T. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-7 · Cited by 463
Bicuspid Aortic Valve: Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns
Hope, M. D., Hope, T. A., Meadows, A. K., Ordovas, K. G., Urbania, T. H., Alley, M. T., & Higgins, C. B. (2010) · Radiology · doi:10.1148/radiol.09091437 · Cited by 417
Self-citation
Metadata
- Authors
- Bammer, R., Hope, T. A., Aksoy, M., & Alley, M. T.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-12-28
- Volume
- 57
- Issue
- 1
- Pages
- 127-140
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2009722017
- Cited by
- 169
- References
- 0
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Time‐resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging. https://app.cochat.ai/papers/10.1002/mrm.21109
- The paper
- Bammer, R., Hope, T. A., Aksoy, M., & Alley, M. T. (2007). Time‐resolved 3D quantitative flow MRI of the major intracranial vessels: Initial experience and comparative evaluation at 1.5T and 3.0T in combination with parallel imaging. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.