The DOI matches its Crossref record.
Novel method for rapid, simultaneous T1, T*2, and proton density quantification
Open accessAbstract
An imaging method called “quantification of relaxation times and proton density by twin‐echo saturation‐recovery turbo‐field echo” (QRAPTEST) is presented as a means of quickly determining the longitudinal T1 and transverse T relaxation time and proton density (PD) within a single sequence. The method also includes an estimation of the B1 field inhomogeneity. High‐resolution images covering large volumes can be achieved within clinically acceptable times of 5–10 min. The range of accuracy for determining T1, T, and PD values is flexible and can be optimized relative to any anticipated values. We validated the experimental results against existing methods, and provide a clinical example in which quantification of the whole brain using 1.5 mm3 voxels was achieved in less than 8 min. Magn Reson Med 57:528–537, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577
“Thus robust, fully quantitative multiparametric acquisition has long been the goal of research in MR 5-8 .”
Rapid magnetic resonance quantification on the brain: Optimization for clinical usage
Warntjes, J. B. M., Leinhard, O. D., West, J., & Lundberg, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21635 · Cited by 500
Self-citationJiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
Tanenbaum, L. N., Tsiouris, A. J., Johnson, A. N., Naidich, T. P., DeLano, M. C., Melhem, E. R., Quarterman, P., Parameswaran, S. X., Shankaranarayanan, A., Goyen, M., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5227 · Cited by 296
Van de Moortele, P.-F., Auerbach, E. J., Olman, C., Yacoub, E., Uğurbil, K., & Moeller, S. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.009 · Cited by 265
European Society of Radiology (ESR) (2015) · Insights into Imaging · doi:10.1007/s13244-015-0403-3 · Cited by 59
Rieger, B., Akçakaya, M., Pariente, J. C., Llufriu, S., Martinez-Heras, E., Weingärtner, S., & Schad, L. R. (2018) · Scientific Reports · doi:10.1038/s41598-018-24920-z · Cited by 39
Metadata
- Authors
- Warntjes, J. B. M., Dahlqvist, O., & Lundberg, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-02-26
- Volume
- 57
- Issue
- 3
- Pages
- 528-537
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2068155703
- Cited by
- 219
- References
- 0
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.