The DOI matches its Crossref record.
T2‐prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo
Open accessAbstract
T2‐weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2‐weighted imaging of edema uses a turbo spin‐echo (TSE) readout with dark‐blood preparation. Clinical applications of dark‐blood TSE methods can be limited by artifacts such as posterior wall signal loss due to through‐plane motion, and bright subendocardial artifacts due to stagnant blood. Single‐shot imaging with a T2‐prepared SSFP readout provides an alternative to dark‐blood TSE and may be conducted during free breathing. We hypothesized that T2‐prepared SSFP would be a more reliable method than dark‐blood TSE for imaging of edema in patients with MI. In patients with MI (22 acute and nine chronic MI cases), T2‐weighted imaging with both methods was performed prior to contrast administration and delayed‐enhancement imaging. The T2‐weighted images using TSE were nondiagnostic in three of 31 cases, while six additional cases rated as being of diagnostic quality yielded incorrect diagnoses. In all 31 cases the T2‐prepared SSFP images were rated as diagnostic quality, correctly differentiated acute or chronic MI, and correctly determined the coronary territory. Free‐breathing T2‐prepared SSFP provides T2‐weighted images of acute MI with fewer artifacts and better diagnostic accuracy than conventional dark‐blood TSE. Magn Reson Med 57:891–897, 2007. Published 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiovascular Magnetic Resonance in Myocarditis: A JACC White Paper
Friedrich, M. G., Sechtem, U., Schulz-Menger, J., Holmvang, G., Alakija, P., Cooper, L. T., White, J. A., Abdel-Aty, H., Gutberlet, M., Prasad, S., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.007 · Cited by 2,509
Self-citationCardiovascular Magnetic Resonance in Nonischemic Myocardial Inflammation
Ferreira, V. M., Schulz-Menger, J., Holmvang, G., Kramer, C. M., Carbone, I., Sechtem, U., Kindermann, I., Gutberlet, M., Cooper, L. T., Liu, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.072 · Cited by 2,059
Wong, T. C., Piehler, K., Meier, C. G., Testa, S. M., Klock, A. M., Aneizi, A. A., Shakesprere, J., Kellman, P., Shroff, S. G., Schwartzman, D. S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.089409 · Cited by 493
Self-citationThe Role of Cardiovascular Magnetic Resonance Imaging in Heart Failure
Karamitsos, T. D., Francis, J. M., Myerson, S., Selvanayagam, J. B., & Neubauer, S. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.04.094 · Cited by 467
Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping
Chow, K., Flewitt, J. A., Green, J. D., Pagano, J. J., Friedrich, M. G., & Thompson, R. B. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24878 · Cited by 396
Metadata
- Authors
- Kellman, P., Aletras, A. H., Mancini, C., McVeigh, E. R., & Arai, A. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-04-24
- Volume
- 57
- Issue
- 5
- Pages
- 891-897
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2136015363
- Cited by
- 247
- References
- 0
- FWCI
- 10.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: T2‐prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo. https://app.cochat.ai/papers/10.1002/mrm.21215
- The paper
- Kellman, P., Aletras, A. H., Mancini, C., McVeigh, E. R., & Arai, A. E. (2007). T2‐prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.