The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping
Open accessAbstract
Purpose: To validate a new saturation recovery single‐shot acquisition (SASHA) pulse sequence for T1 mapping and to compare SASHA T1 values in heart failure patients and healthy controls. Theory: The SASHA sequence consists of 10 electrocardiogram‐triggered single‐shot balanced steady‐state free precession images in a breath‐hold. The first image is acquired without magnetization preparation and the remaining nine images follow saturation pulses with variable saturation recovery times. Methods: SASHA was validated through Bloch equation simulations, Monte Carlo simulations, and phantom experiments. Pre‐ and postcontrast myocardial and blood T1 values were measured in 29 healthy volunteers and 7 patients with heart failure. Results: SASHA T1 values had excellent agreement (bias, 5 ± 5 ms) with spin echo experiments in phantoms with a wide range of physiologic T1 and T2 values and its accuracy was independent of flip angle, absolute T1, T2, and heart rate. The average baseline myocardial T1 in heart failure patients was higher than in healthy controls (1200 ± 32 vs. 1170 ± 9 ms, P < 0.05) at 1.5T, as was the calculated blood–tissue partition coefficient, λ, (0.42 ± 0.04 vs. 0.38 ± 0.02, P < 0.05), consistent with diffuse myocardial fibrosis. Conclusions: The SASHA sequence is a simple and fast approach to in vivo T1 mapping with good accuracy in simulations and phantom experiments. Magn Reson Med 71:2082–2095, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
American Heart Association Writing Group on Myocardial Segmentation and Registration for Cardiac Imaging:, Cerqueira, M. D., Weissman, N. J., Dilsizian, V., Jacobs, A. K., Kaul, S., Laskey, W. K., Pennell, D. J., Rumberger, J. A., Ryan, T., et al. (2002) · Circulation · doi:10.1161/hc0402.102975 · Cited by 6,990
Elastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311
Jessup, M., & Brozena, S. (2003) · New England Journal of Medicine · doi:10.1056/nejmra021498 · Cited by 1,564
Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349
Flett, A. S., Hayward, M. P., Ashworth, M. T., Hansen, M. S., Taylor, A. M., Elliott, P. M., McGregor, C., & Moon, J. C. (2010) · Circulation · doi:10.1161/circulationaha.109.930636 · Cited by 915
Time Saving in Measurement of NMR and EPR Relaxation Times
Look, D. C., & Locker, D. R. (1970) · Review of Scientific Instruments · doi:10.1063/1.1684482 · Cited by 819
Mechanisms and Models in Heart Failure: A Combinatorial Approach
Mann, D. L. (1999) · Circulation · doi:10.1161/01.cir.100.9.999 · Cited by 773
Iles, L., Pfluger, H., Phrommintikul, A., Cherayath, J., Aksit, P., Gupta, S. N., Kaye, D. M., & Taylor, A. J. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.06.049 · Cited by 736
Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla
Lu, H., Clingman, C., Golay, X., & van Zijl, P. C. M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20178 · Cited by 685
Cited by
Normal values for cardiovascular magnetic resonance in adults and children
Kawel-Boehm, N., Maceira, A., Valsangiacomo-Buechel, E. R., Vogel-Claussen, J., Turkbey, E. B., Williams, R., Plein, S., Tee, M., Eng, J., & Bluemke, D. A. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0111-7 · Cited by 746
Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging
Christodoulou, A. G., Shaw, J. L., Nguyen, C., Yang, Q., Xie, Y., Wang, N., & Li, D. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0217-y · Cited by 323
Metadata
- Authors
- Chow, K., Flewitt, J. A., Green, J. D., Pagano, J. J., Friedrich, M. G., & Thompson, R. B.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2013-07-23
- Volume
- 71
- Issue
- 6
- Pages
- 2082-2095
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2149392970
- Cited by
- 396
- References
- 32
- FWCI
- 24.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping. https://app.cochat.ai/papers/10.1002/mrm.24878
- The paper
- Chow, K., Flewitt, J. A., Green, J. D., Pagano, J. J., Friedrich, M. G., & Thompson, R. B. (2014). Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24878
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.