The DOI matches its Crossref record.
In vivo 13carbon metabolic imaging at 3T with hyperpolarized 13C‐1‐pyruvate
Open accessAbstract
We present for the first time dynamic spectra and spectroscopic images acquired in normal rats at 3T following the injection of 13 C‐1‐pyruvate that was hyperpolarized by the dynamic nuclear polarization (DNP) method. Spectroscopic sampling was optimized for signal‐to‐noise ratio (SNR) and for spectral resolution of 13 C‐1‐pyruvate and its metabolic products 13 C‐1‐alanine, 13 C‐1‐lactate, and 13 C‐bicarbonate. Dynamic spectra in rats were collected with a temporal resolution of 3 s from a 90‐mm axial slab using a dual 1 H‐13 C quadrature birdcage coil to observe the combined effects of metabolism, flow, and T1 relaxation. In separate experiments, spectroscopic imaging data were obtained during a 17‐s acquisition of a 20‐mm axial slice centered on the rat kidney region to provide information on the spatial distribution of the metabolites. Conversion of pyruvate to lactate, alanine, and bicarbonate occurred within a minute of injection. Alanine was observed primarily in skeletal muscle and liver, while pyruvate, lactate, and bicarbonate concentrations were relatively high in the vasculature and kidneys. In contrast to earlier work at 1.5T, bicarbonate was routinely observed in skeletal muscle as well as the kidney and vasculature. Magn Reson Med 58:65–69, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kurhanewicz, J., Vigneron, D. B., Brindle, K., Chekmenev, E. Y., Comment, A., Cunningham, C. H., DeBerardinis, R. J., Green, G. G., Leach, M. O., Rajan, S. S., et al. (2011) · Neoplasia · doi:10.1593/neo.101102 · Cited by 681
Self-citationXie, H., Hanai, J.-I., Ren, J.-G., Kats, L., Burgess, K., Bhargava, P., Signoretti, S., Billiard, J., Duffy, K. J., Grant, A., et al. (2014) · Cell Metabolism · doi:10.1016/j.cmet.2014.03.003 · Cited by 516
Albers, M. J., Bok, R., Chen, A. P., Cunningham, C. H., Zierhut, M. L., Zhang, V. Y., Kohler, S. J., Tropp, J., Hurd, R. E., Yen, Y.-F., et al. (2008) · Cancer Research · doi:10.1158/0008-5472.can-08-0749 · Cited by 520
Self-citationKeshari, K. R., & Wilson, D. M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60124b · Cited by 358
MRI in multiple sclerosis: current status and future prospects
Bakshi, R., Thompson, A. J., Rocca, M. A., Pelletier, D., Dousset, V., Barkhof, F., Inglese, M., Guttmann, C. R., Horsfield, M. A., & Filippi, M. (2008) · The Lancet Neurology · doi:10.1016/s1474-4422(08)70137-6 · Cited by 348
Metadata
- Authors
- Kohler, S. J., Yen, Y., Wolber, J., Chen, A. P., Albers, M. J., Bok, R., Zhang, V., Tropp, J., Nelson, S., Vigneron, D. B., Kurhanewicz, J., & Hurd, R. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2007-07
- Volume
- 58
- Issue
- 1
- Pages
- 65-69
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2142499796
- Cited by
- 191
- References
- 0
- FWCI
- 7.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo 13carbon metabolic imaging at 3T with hyperpolarized 13C‐1‐pyruvate. https://app.cochat.ai/papers/10.1002/mrm.21253
- The paper
- Kohler, S. J., Yen, Y., Wolber, J., Chen, A. P., Albers, M. J., Bok, R., Zhang, V., Tropp, J., Nelson, S., Vigneron, D. B., Kurhanewicz, J., & Hurd, R. E. (2007). In vivo 13carbon metabolic imaging at 3T with hyperpolarized 13C‐1‐pyruvate. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21253
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.