Open accessAbstract
For T1ρ quantification, a three‐dimensional (3D) acquisition is desired to obtain high‐resolution images. Current 3D methods that use steady‐state spoiled gradient‐echo (SPGR) imaging suffer from high SAR, low signal‐to‐noise ratio (SNR), and the need for retrospective correction of contaminating T1 effects. In this study, a novel 3D acquisition scheme—magnetization‐prepared angle‐modulated partitioned‐k‐space SPGR snapshots (3D MAPSS)—was developed and used to obtain in vivo T1ρ maps. Transient signal evolving towards the steady‐state were acquired in an interleaved segmented elliptical centric phase encoding order immediately after a T1ρ magnetization preparation sequence. RF cycling was applied to eliminate the adverse impact of longitudinal relaxation on quantitative accuracy. A variable flip angle train was designed to provide a flat signal response to eliminate the filtering effect in k‐space caused by transient signal evolution. Experiments in phantoms agreed well with results from simulation. The T1ρ values were 42.4 ± 5.2 ms in overall cartilage of healthy volunteers. The average coefficient‐of‐variation (CV) of mean T1ρ values (N = 4) for overall cartilage was 1.6%, with regional CV ranging from 1.7% to 8.7%. The fitting errors using MAPSS were significantly lower (P < 0.05) than those using sequences without RF cycling and variable flip angles. Magn Reson Med 59:298–307, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Cited by
Fortier, L. A., Potter, H. G., Rickey, E. J., Schnabel, L. V., Foo, L. F., Chong, L. R., Stokol, T., Cheetham, J., & Nixon, A. J. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01284 · Cited by 426
Advances in Imaging of Osteoarthritis and Cartilage
Roemer, F. W., Crema, M. D., Trattnig, S., & Guermazi, A. (2011) · Radiology · doi:10.1148/radiol.11101359 · Cited by 220
Metadata
- Authors
- Li, X., Han, E. T., Busse, R. F., & Majumdar, S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-01-28
- Volume
- 59
- Issue
- 2
- Pages
- 298-307
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2061344292
- Cited by
- 197
- References
- 1
- FWCI
- 7.41
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo T1ρ mapping in cartilage using 3D magnetization‐prepared angle‐modulated partitioned k‐space spoiled gradient echo snapshots (3D MAPSS). https://app.cochat.ai/papers/10.1002/mrm.21414
- The paper
- Li, X., Han, E. T., Busse, R. F., & Majumdar, S. (2008). In vivo T1ρ mapping in cartilage using 3D magnetization‐prepared angle‐modulated partitioned k‐space spoiled gradient echo snapshots (3D MAPSS). Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21414
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.