ACUT2E TSE‐SSFP: A hybrid method for T2‐weighted imaging of edema in the heart
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
ACUT 2 E TSE‐SSFP is a hybrid between steady state free precession (SSFP) and turbo spin echo (TSE) for bright‐blood T2‐weighted imaging with signal‐to‐noise ratio (SNR) and contrast‐to‐noise ratio (CNR) similar to dark‐blood TSE. TSE‐SSFP uses a segmented SSFP readout during diastole with 180° pulses following a 90° preparation. The 180° refocusing pulses make TSE‐SSFP similar to TSE but TSE‐SSFP uses gradient moment nulling, whereas TSE uses gradient crushing. TSE‐SSFP produced T2‐weighted images with minimal T1 weighting. TSE‐SSFP and TSE had similar SNR (155.9 ± 6.0 vs 160.9 ± 7.0; P = NS) for acute myocardial infarction (MI) and twice the SNR of T2‐prepared SSFP (73.1 ± 3.4, P < 0.001). TSE‐SSFP and TSE had approximately double the CNR of T2‐prepared SSFP for differentiating acute MI from normal myocardium. Imperfect blood suppression, present in all animals on some TSE images, was a problem eliminated by TSE‐SSFP and T2‐prepared SSFP. Magn Reson Med 59:229–235, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Cited by
Caforio, A. L. P., Pankuweit, S., Arbustini, E., Basso, C., Gimeno-Blanes, J., Felix, S. B., Fu, M., Heliö, T., Heymans, S., Jahns, R., et al. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht210 · Cited by 3,479
Cardiovascular Magnetic Resonance in Myocarditis: A JACC White Paper
Friedrich, M. G., Sechtem, U., Schulz-Menger, J., Holmvang, G., Alakija, P., Cooper, L. T., White, J. A., Abdel-Aty, H., Gutberlet, M., Prasad, S., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.007 · Cited by 2,509
Self-citationCardiovascular Magnetic Resonance in Nonischemic Myocardial Inflammation
Ferreira, V. M., Schulz-Menger, J., Holmvang, G., Kramer, C. M., Carbone, I., Sechtem, U., Kindermann, I., Gutberlet, M., Cooper, L. T., Liu, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.072 · Cited by 2,059
Kindermann, I., Barth, C., Mahfoud, F., Ukena, C., Lenski, M., Yilmaz, A., Klingel, K., Kandolf, R., Sechtem, U., Cooper, L. T., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.074 · Cited by 919
T2 quantification for improved detection of myocardial edema
Giri, S., Chung, Y.-C., Merchant, A., Mihai, G., Rajagopalan, S., Raman, S. V., & Simonetti, O. P. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-56 · Cited by 680
Metadata
- Authors
- Aletras, A. H., Kellman, P., Derbyshire, J. A., & Arai, A. E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-01-28
- Volume
- 59
- Issue
- 2
- Pages
- 229-235
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2167468755
- Cited by
- 141
- References
- 2
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.