The DOI matches its Crossref record.
Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels
Open accessAbstract
Spatially tailored radio frequency (RF) excitations accelerated with parallel transmit systems provide the opportunity to create shaped volume excitations or mitigate inhomogeneous B 1 excitation profiles with clinically relevant pulse lengths. While such excitations are often designed as a least‐squares optimized approximation to a target magnitude and phase profile, adherence to the target phase profile is usually not important as long as the excitation phase is slowly varying compared with the voxel dimension. In this work, we demonstrate a method for a magnitude least squares optimization of the target magnetization profile for multichannel parallel excitation to improve the magnitude profile and reduce the RF power at the cost of a less uniform phase profile. The method enables the designer to trade off the allowed spatial phase variation for the improvement in magnitude profile and reduction in RF power. We validate the method with simulation studies and demonstrate its performance in fourfold accelerated two‐dimensional spiral excitations, as well as for uniform in‐plane slice selective parallel excitations using an eight‐channel transmit array on a 7T human MRI scanner. The experimental results are in good agreement with the simulations, which show significant improvement in the magnitude profile and reductions in the required RF power while still maintaining negligible intravoxel phase variation. Magn Reson Med 59:908–915, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545
Self-citationDREAM—a novel approach for robust, ultrafast, multislice B1 mapping
Nehrke, K., & Börnert, P. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24158 · Cited by 282
Metadata
- Authors
- Setsompop, K., Wald, L. L., Alagappan, V., Gagoski, B. A., & Adalsteinsson, E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-03-27
- Volume
- 59
- Issue
- 4
- Pages
- 908-915
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2040940761
- Cited by
- 228
- References
- 0
- FWCI
- 8.60
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels. https://app.cochat.ai/papers/10.1002/mrm.21513
- The paper
- Setsompop, K., Wald, L. L., Alagappan, V., Gagoski, B. A., & Adalsteinsson, E. (2008). Magnitude least squares optimization for parallel radio frequency excitation design demonstrated at 7 Tesla with eight channels. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21513
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.