The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
DREAM—a novel approach for robust, ultrafast, multislice B1 mapping
Abstract
A novel multislice B1‐mapping method dubbed dual refocusing echo acquisition mode is proposed, able to cover the whole transmit coil volume in only one second, which is more than an order of magnitude faster than established approaches. The dual refocusing echo acquisition mode technique employs a stimulated echo acquisition mode (STEAM) preparation sequence followed by a tailored single‐shot gradient echo sequence, measuring simultaneously the stimulated echo and the free induction decay as gradient‐recalled echoes, and determining the actual flip angle of the STEAM preparation radiofrequency pulses from the ratio of the two measured signals. Due to an elaborated timing scheme, the method is insensitive against susceptibility/chemical shift effects and can deliver a B0 phase map and a transceive phase map for free. The approach has only a weak T1 and T2 dependence and moreover, causes only a low specific absorption rate (SAR) burden. The accuracy of the method with respect to systematic and statistical errors is investigated both, theoretically and in experiments on phantoms. In addition, the performance of the approach is demonstrated in vivo in B1‐mapping and radiofrequency shimming experiments on the abdomen, the legs, and the head on an eight‐channel parallel transmit 3 T MRI system. Magn Reson Med, 2012. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Yarnykh, V. L. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,026
Katscher, U., Börnert, P., Leussler, C., & van den Brink, J. S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10353 · Cited by 719
Self-citationSnapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
B1 mapping by Bloch‐Siegert shift
Sacolick, L. I., Wiesinger, F., Hancu, I., & Vogel, M. W. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22357 · Cited by 529
Imaging of the active B1 field in vivo
Stollberger, R., & Wach, P. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910350217 · Cited by 357
Saturated double‐angle method for rapid B1+ mapping
Cunningham, C. H., Pauly, J. M., & Nayak, K. S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20896 · Cited by 353
Determination of Electric Conductivity and Local SAR Via B1 Mapping
Katscher, U., Voigt, T., Findeklee, C., Vernickel, P., Nehrke, K., & DÖssel, O. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2015757 · Cited by 329
Self-citationMapping of the Radiofrequency Field
Insko, E. K., & Bolinger, L. (1993) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1993.1133 · Cited by 323
Rapid B1+ mapping using a preconditioning RF pulse with TurboFLASH readout
Chung, S., Kim, D., Breton, E., & Axel, L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22423 · Cited by 304
Cited by
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Using high-resolution quantitative mapping of R1 as an index of cortical myelination
Lutti, A., Dick, F., Sereno, M. I., & Weiskopf, N. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.005 · Cited by 346
Teixeira, R. P. A. G., Malik, S. J., & Hajnal, J. V. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26670 · Cited by 39
Metadata
- Authors
- Nehrke, K., & Börnert, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-01-17
- Volume
- 68
- Issue
- 5
- Pages
- 1517-1526
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2107855009
- Cited by
- 282
- References
- 24
- FWCI
- 13.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DREAM—a novel approach for robust, ultrafast, multislice B1 mapping. https://app.cochat.ai/papers/10.1002/mrm.24158
- The paper
- Nehrke, K., & Börnert, P. (2012). DREAM—a novel approach for robust, ultrafast, multislice B1 mapping. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24158
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.