Compartment size estimation with double wave vector diffusion‐weighted imaging
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Double wave vector diffusion weighting uses gradients along two different directions between excitation and acquisition. It has been shown theoretically that for restricted diffusion the signal amplitude in such an experiment can depend on the angle between the two gradient vectors. The highest amplitude is obtained with antiparallel orientation, and the amplitude difference between parallel and antiparallel gradient orientations depends on the compartment size. The validity of this description is experimentally tested for water between polymer beads, for radish, and for porcine spinal cord, using a clinical MR system with limited gradient strength. The results indicate that the phenomenon is observable; however, the size of the signal difference is considerably diminished when compared with theory. This is attributed to violations of the approximating conditions underlying the theoretical description and to free diffusion contributions. It is concluded that the effect could successfully be used as a basis for developing a new noninvasive method for assessing cell size. Magn Reson Med, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Cited by
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
“, 2003) or double wave-vector (Komlosh et al., 2008; Koch and Finsterbusch, 2008; Ozarslan and Basser, 2007) experiments, which may be more sensitive to microstructural parameters.”
BackgroundQuantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Imaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422
“…sequences, such as oscillating gradients (Callaghan and Stepisnik, 1995; Does et al., 2003; Drobnjak et al., 2010), twice-refocused spin echo sequences (Clayden et al., 2009; Reese et al., 2003), or double wave vector sequences (Koch and Finsterbusch, 2008; Mitra, 1995; Shemesh et al., 2009).”
Measuring macroscopic brain connections in vivo
Jbabdi, S., Sotiropoulos, S. N., Haber, S. N., Van Essen, D. C., & Behrens, T. E. (2015) · Nature Neuroscience · doi:10.1038/nn.4134 · Cited by 334
Metadata
- Authors
- Koch, M. A., & Finsterbusch, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-04-17
- Volume
- 60
- Issue
- 1
- Pages
- 90-101
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1984016709
- Cited by
- 100
- References
- 1
- FWCI
- 8.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.