The DOI matches its Crossref record.
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Abstract
A derivation is given of the effect of a time-dependent magnetic field gradient on the spin-echo experiment, particularly in the presence of spin diffusion. There are several reasons for preferring certain kinds of time-dependent magnetic field gradients to the more usual steady gradient. If the gradient is reduced during the rf pulses, H1 need not be particularly large; if the gradient is small at the time of the echo, the echo will be broad and its amplitude easy to measure. Both of these relaxations of restrictions on the measurement of diffusion coefficients by the spin-echo technique serve to extend its range of applicability. Furthermore, a pulsed gradient can be recommended when it is critical to define the precise time period over which diffusion is being measured. The theoretical expression derived has been verified experimentally for several choices of time dependent magnetic field gradient. An apparatus is described suitable for the production of pulsed gradients with amplitudes as large as 100 G cm−1. The diffusion coefficient of dry glycerol at 26°±1°C has been found to be (2.5±0.2)×10−8 cm2 sec−1, a value smaller than can ordinarily be measured by the steady gradient method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 13
- 1950, Phys. Rev., 80, 580, 10.1103/PhysRev.80.580 · DOI
- 1953, Phys. Today, 6, 4, 10.1063/1.3061075 · DOI
- 1954, Phys. Rev., 94, 630, 10.1103/PhysRev.94.630 · DOI
- 1961, J. Chem. Phys., 34, 2057, 10.1063/1.1731821 · DOI
- 1963, Ber. Bunsenges. Physik. Chem., 67, 336, 10.1002/bbpc.19630670312 · DOI
- 1963, J. Phys. Chem., 67, 1365, 10.1021/j100800a509 · DOI
- 1955, J. Appl. Phys., 26, 1324, 10.1063/1.1721903 · DOI
- 1956, Phys. Rev., 104, 563, 10.1103/PhysRev.104.563 · DOI · Paper page
- 1963, Rev. Sci. Instr., 34, 971, 10.1063/1.1718665 · DOI
- 1958, Rev. Sci. Instr., 29, 55, 10.1063/1.1716004 · DOI
- 1958, Phys. Rev., 111, 1201, 10.1103/PhysRev.111.1201 · DOI · Paper page
- 1956, Chem. Rev., 56, 387, 10.1021/cr50009a001 · DOI
- 1959, J. Chem. Phys., 31, 1555, 10.1063/1.1730651 · DOI
Cited by
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Tuch, D. S. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20279 · Cited by 1,880
Tracking neuronal fiber pathways in the living human brain
Conturo, T. E., Lori, N. F., Cull, T. S., Akbudak, E., Snyder, A. Z., Shimony, J. S., McKinstry, R. C., Burton, H., & Raichle, M. E. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10422 · Cited by 1,774
Metadata
- Authors
- Stejskal, E. O., & Tanner, J. E.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1965-01-01
- Volume
- 42
- Issue
- 1
- Pages
- 288-292
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W2084761689
- Cited by
- 8,286
- References
- 0
- FWCI
- 4.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient. https://app.cochat.ai/papers/10.1063/1.1695690
- The paper
- Stejskal, E. O., & Tanner, J. E. (1965). Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient. The Journal of Chemical Physics. https://doi.org/10.1063/1.1695690
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).