CoChat

Robust MRI brain tissue parameter estimation by multistage outlier rejection

Open access
Manjón, José V., Tohka, Jussi, García‐Martí, Gracian, Carbonell‐Caballero, José, Lull, Juan J., Martí‐Bonmatí, Luís, Robles, Montserrat · 2008 · Magnetic Resonance in Medicine
Cited by 62

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

This article addresses the problem of the tissue type parameter estimation in brain MRI in the presence of partial volume effects. Automatic MRI brain tissue classification is hampered by partial volume effects that are caused by the finite resolution of the acquisition process. Due to this effect intensity distributions in brain MRI cannot be well modeled by a simple mixture of Gaussians and therefore more complex models have been developed. Unfortunately, these models do not seem to be robust enough for clinical conditions, as the quality of the tissue classification decreases rapidly with the image quality. Also, the application of these methods for pathological images with unmodeled intensities (e.g. MS plaques, tumors, etc.) remains uncertain. In the present work a new robust method for brain tissue characterization is presented, treating the partial volume affected voxels as outliers of the pure tissue distributions. The proposed method estimates the tissue characteristics from a reduced set of intensities belonging to a particular pure tissue class. This reduced set is selected by using a trimming procedure based on local gradient information and distributional data. This feature makes the method highly tolerant of a large amount of unexpected intensities without degrading its performance. The proposed method has been evaluated using both synthetic and real MR data and compared with state‐of‐the‐art methods showing the best results in the comparative. Magn Reson Med 59:866–873, 2008. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21521

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Manjón, J. V., Tohka, J., García‐Martí, G., Carbonell‐Caballero, J., Lull, J. J., Martí‐Bonmatí, L., & Robles, M.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2008-03-27
Volume
59
Issue
4
Pages
866-873
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2066766733
Cited by
62
References
1
FWCI
3.82
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.