Robust MRI brain tissue parameter estimation by multistage outlier rejection
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This article addresses the problem of the tissue type parameter estimation in brain MRI in the presence of partial volume effects. Automatic MRI brain tissue classification is hampered by partial volume effects that are caused by the finite resolution of the acquisition process. Due to this effect intensity distributions in brain MRI cannot be well modeled by a simple mixture of Gaussians and therefore more complex models have been developed. Unfortunately, these models do not seem to be robust enough for clinical conditions, as the quality of the tissue classification decreases rapidly with the image quality. Also, the application of these methods for pathological images with unmodeled intensities (e.g. MS plaques, tumors, etc.) remains uncertain. In the present work a new robust method for brain tissue characterization is presented, treating the partial volume affected voxels as outliers of the pure tissue distributions. The proposed method estimates the tissue characteristics from a reduced set of intensities belonging to a particular pure tissue class. This reduced set is selected by using a trimming procedure based on local gradient information and distributional data. This feature makes the method highly tolerant of a large amount of unexpected intensities without degrading its performance. The proposed method has been evaluated using both synthetic and real MR data and compared with state‐of‐the‐art methods showing the best results in the comparative. Magn Reson Med 59:866–873, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Regression and Outlier Detection
Rousseeuw, P. J., & Leroy, A. M. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/0471725382 · Cited by 5,609
Cited by
volBrain: An Online MRI Brain Volumetry System
Manjón, J. V., & Coupé, P. (2016) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2016.00030 · Cited by 626
Self-citationAssemblyNet: A large ensemble of CNNs for 3D whole brain MRI segmentation
Coupé, P., Mansencal, B., Clément, M., Giraud, R., Denis de Senneville, B., Ta, V.-T., Lepetit, V., & Manjon, J. V. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117026 · Cited by 206
Sudre, C. H., Cardoso, M. J., Bouvy, W. H., Biessels, G. J., Barnes, J., & Ourselin, S. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2419072 · Cited by 162
“These approaches consist of the down-weighting of the responsibility of the voxels considered as outliers when estimating the parameters [5], [7], [29] or the introduction of an outlier-specific class, thus reducing the bias introduced by the outliers into the parameter estimates of the normal tissue classes [5], [6].”
BackgroundSpalletta, G., Piras, F., Fagioli, S., Caltagirone, C., & Piras, F. (2014) · Brain and Behavior · doi:10.1002/brb3.212 · Cited by 50
Lalousis, P. A., Wood, S. J., Schmaal, L., Chisholm, K., Griffiths, S. L., Reniers, R. L. E. P., Bertolino, A., Borgwardt, S., Brambilla, P., Kambeitz, J., et al. (2021) · Schizophrenia Bulletin · doi:10.1093/schbul/sbaa185 · Cited by 42
Metadata
- Authors
- Manjón, J. V., Tohka, J., García‐Martí, G., Carbonell‐Caballero, J., Lull, J. J., Martí‐Bonmatí, L., & Robles, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-03-27
- Volume
- 59
- Issue
- 4
- Pages
- 866-873
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2066766733
- Cited by
- 62
- References
- 1
- FWCI
- 3.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.