The DOI matches its Crossref record.
Joint estimation of water/fat images and field inhomogeneity map
Open accessAbstract
Water/fat separation in the presence of B0 field inhomogeneity is a problem of considerable practical importance in MRI. This article describes two complementary methods for estimating the water/fat images and the field inhomogeneity map from Dixon‐type acquisitions. One is based on variable projection (VARPRO) and the other on linear prediction (LP). The VARPRO method is very robust and can be used in low signal‐to‐noise ratio conditions because of its ability to achieve the maximum‐likelihood solution. The LP method is computationally more efficient, and is shown to perform well under moderate levels of noise and field inhomogeneity. These methods have been extended to handle multicoil acquisitions by jointly solving the estimation problem for all the coils. Both methods are analyzed and compared and results from several experiments are included to demonstrate their performance. Magn Reson Med 59:571–580, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Liu, T., Spincemaille, P., de Rochefort, L., Kressler, B., & Wang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21828 · Cited by 454
Quantification of Liver Fat with Magnetic Resonance Imaging
Reeder, S. B., & Sirlin, C. B. (2010) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2010.08.013 · Cited by 342
Hernando, D., Kellman, P., Haldar, J. P., & Liang, Z. ‐. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22177 · Cited by 336
Self-citation
Metadata
- Authors
- Hernando, D., Haldar, J. P., Sutton, B. P., Ma, J., Kellman, P., & Liang, Z. ‐.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-02-27
- Volume
- 59
- Issue
- 3
- Pages
- 571-580
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2166997774
- Cited by
- 183
- References
- 0
- FWCI
- 9.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Joint estimation of water/fat images and field inhomogeneity map. https://app.cochat.ai/papers/10.1002/mrm.21522
- The paper
- Hernando, D., Haldar, J. P., Sutton, B. P., Ma, J., Kellman, P., & Liang, Z. ‐. (2008). Joint estimation of water/fat images and field inhomogeneity map. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21522
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.