High‐resolution myelin water measurements in rat spinal cord
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Multiecho imaging data were acquired at 7T from control and injured (dorsal column transection) rat spinal cords ex vivo with in‐plane resolution of 61, 78, and 100 μm, and from a control rat spinal cord in vivo with in‐plane resolution of 117 μm. The myelin water maps were calculated using nonnegative least‐squares (NNLS) analysis of the decay curves. For the control cords, myelin water maps showed details of the cord morphology, and the average myelin water fraction (MWF) values in white matter and gray matter corresponded well with previously published results and the expected amounts of myelin within the cord, and correlated very well with Luxol Fast Blue stain (R 2 = 0.95). Myelin water maps from an injured cord showed excellent qualitative correlation with histology. This pilot study demonstrates that high‐resolution myelin water mapping in rat spinal cord is feasible, and this technique has potential to be a valuable tool in studying white matter damage in rat models of spinal cord injury. Magn Reson Med, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Myelin water imaging in multiple sclerosis: quantitative correlations with histopathology
Laule, C., Leung, E., Li, D. K., Traboulsee, A. L., Paty, D. W., MacKay, A. L., & Moore, G. R. (2006) · Multiple Sclerosis Journal · doi:10.1177/1352458506070928 · Cited by 489 · cited 6×
“The T2 distribution has been used extensively in studying the demyelination process in MS patients (10) and it has been shown that MWF correlates well with the amount of myelin measured by histology (9).”
BackgroundInfluentialMR properties of excised neural tissue following experimentally induced inflammation
Stanisz, G. J., Webb, S., Munro, C. A., Pun, T., & Midha, R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20008 · Cited by 138 · cited 2×
“Thus, few studies have reported the application of the T2 distribution in animal CNS (15,16); many have applied a nonimaging CPMG pulse sequence to acquire nonlocalized continuous T2 distributions from the excised tissue.”
BackgroundMyelin Water Fraction in Human Cervical Spinal Cord In Vivo
Wu, Y., Alexander, A. L., Fleming, J. O., Duncan, I. D., & Field, A. S. (2006) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-200603000-00026 · Cited by 51 · cited 2×
“1) compare favorably with previously published results (17,18,20).”
BackgroundResult
Cited by
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Magnetic Resonance of Myelin Water: An in vivo Marker for Myelin
MacKay, A. L., & Laule, C. (2016) · Brain Plasticity · doi:10.3233/bpl-160033 · Cited by 284
Cohen-Adad, J., El Mendili, M.-M., Lehéricy, S., Pradat, P.-F., Blancho, S., Rossignol, S., & Benali, H. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.089 · Cited by 242
“Notably, myelin water fraction estimated from the short T2 relaxation of water trapped within myelin sheets is another measure that correlates with myelin content (Kozlowski et al., 2008; Laule et al., 2006).”
BackgroundQuantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination
Thiessen, J. D., Zhang, Y., Zhang, H., Wang, L., Buist, R., Del Bigio, M. R., Kong, J., Li, X., & Martin, M. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2992 · Cited by 148
So You Want to Image Myelin Using MRI: An Overview and Practical Guide for Myelin Water Imaging
Lee, J., Hyun, J., Lee, J., Choi, E., Shin, H., Min, K., Nam, Y., Kim, H. J., & Oh, S. (2021) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.27059 · Cited by 134
Metadata
- Authors
- Kozlowski, P., Liu, J., Yung, A. C., & Tetzlaff, W.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-02-26
- Volume
- 59
- Issue
- 4
- Pages
- 796-802
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1989462236
- Cited by
- 64
- References
- 3
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.