The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
MR imaging of adventitial vasa vasorum in carotid atherosclerosis
Abstract
Vasa vasorum in the adventitia of atherosclerotic arteries may play a role in plaque progression. In this investigation, a method for characterizing vasa vasorum in the carotid artery is proposed, in which the perfusion properties of the adventitia are probed via dynamic contrast‐enhanced (DCE) MRI. A parametric “vasa vasorum image” is automatically generated that depicts the plasma volume (vp) and transfer constant (Ktrans). The average Ktrans within the adventitia is proposed as a quantitative measurement related to the extent of the vasa vasorum. In 25 subjects with lesions meeting the requirements for carotid endarterectomy (CEA) significantly higher adventitial Ktrans of 0.155 ± 0.045 min–1 was observed, compared to 0.122 ± 0.029 min–1 in the remaining 20 subjects with moderate disease (P < 0.01). In the 25 subjects with endarterectomy specimens, histological evaluation showed that adventitial Ktrans was significantly correlated with the amount of neovasculature (R = 0.41; P = 0.04) and macrophages (R = 0.49; P = 0.01) in the excised plaque. In the remaining 20 subjects without histology, elevated adventitial Ktrans was significantly correlated with the log of C‐reactive protein (CRP) levels (R = 0.57; P = 0.01) and was elevated in active smokers compared to nonsmokers (0.141 ± 0.036 vs. 0.111 ± 0.017 min–1; P = 0.02). Because these factors are all associated with higher risk of atherosclerotic complications, these results suggest that adventitial Ktrans may be a marker of risk as well. Magn Reson Med 59:507–514, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms linking obesity with cardiovascular disease
Van Gaal, L. F., Mertens, I. L., & De Block, C. E. (2006) · Nature · doi:10.1038/nature05487 · Cited by 2,814
Antiinflammatory Properties of HDL
Barter, P. J., Nicholls, S., Rye, K.-A., Anantharamaiah, G. M., Navab, M., & Fogelman, A. M. (2004) · Circulation Research · doi:10.1161/01.res.0000146094.59640.13 · Cited by 1,394
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Winter, P. M., Morawski, A. M., Caruthers, S. D., Fuhrhop, R. W., Zhang, H., Williams, T. A., Allen, J. S., Lacy, E. K., Robertson, J. D., Lanza, G. M., et al. (2003) · Circulation · doi:10.1161/01.cir.0000093185.16083.95 · Cited by 696
Cited by
Mandell, D. M., Mossa-Basha, M., Qiao, Y., Hess, C. P., Hui, F., Matouk, C., Johnson, M. H., Daemen, M. J. A. P., Vossough, A., Edjlali, M., et al. (2017) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4893 · Cited by 691
Contemporary carotid imaging: from degree of stenosis to plaque vulnerability
Brinjikji, W., Huston, J., Rabinstein, A. A., Kim, G.-M., Lerman, A., & Lanzino, G. (2016) · Journal of Neurosurgery · doi:10.3171/2015.1.jns142452 · Cited by 401
Qiao, Y., Zeiler, S. R., Mirbagheri, S., Leigh, R., Urrutia, V., Wityk, R., & Wasserman, B. A. (2014) · Radiology · doi:10.1148/radiol.13122812 · Cited by 329
Saba, L., Yuan, C., Hatsukami, T. S., Balu, N., Qiao, Y., DeMarco, J. K., Saam, T., Moody, A. R., Li, D., Matouk, C. C., et al. (2018) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5488 · Cited by 329
Self-citationModels and methods for analyzing DCE‐MRI: A review
Khalifa, F., Soliman, A., El‐Baz, A., Abou El‐Ghar, M., El‐Diasty, T., Gimel'farb, G., Ouseph, R., & Dwyer, A. C. (2014) · Medical Physics · doi:10.1118/1.4898202 · Cited by 322
Metadata
- Authors
- Kerwin, W. S., Oikawa, M., Yuan, C., Jarvik, G. P., & Hatsukami, T. S.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-02-27
- Volume
- 59
- Issue
- 3
- Pages
- 507-514
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2113809297
- Cited by
- 192
- References
- 4
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.