CoChat

MT effects and T1 quantification in single‐slice spoiled gradient echo imaging

Open access
Ou, Xiawei, Gochberg, Daniel Frank · 2008 · Magnetic Resonance in Medicine
Cited by 61

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

We investigated magnetization transfer (MT) effects on the steady‐state MR signal for a sample subjected to a series of identical on‐resonance RF pulses, such as would be experienced while imaging a single slice using a spoiled gradient echo sequence. The MT coupling terms for a two‐pool system were added to the Bloch equations and we derived the resulting steady‐state signal equation and compared this result to the conventional signal equation without MT effects. The steady‐state signal is increased by a few percent of the equilibrium magnetization because of MT. One consequence of this MT effect is inaccuracy in T1 values determined via conventional steady‐state gradient echo methods. (Theory predicts greater than 10% errors in T1 for white matter when using short TR.) A second consequence is the ability to quantify the relaxation and MT parameters by fitting the gradient echo steady state signal to the signal equation appropriately modified to include MT effects. The theory was tested in samples of MnCl 2, cross‐linked bovine serum albumin (BSA), and cross‐linked BSA + MnCl 2. Magn Reson Med, 2008. © 2008 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.21550

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 61

Metadata

Authors
Ou, X., & Gochberg, D. F.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2008-02-26
Volume
59
Issue
4
Pages
835-845
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2084050824
Cited by
61
References
1
FWCI
2.63
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.