MT effects and T1 quantification in single‐slice spoiled gradient echo imaging
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We investigated magnetization transfer (MT) effects on the steady‐state MR signal for a sample subjected to a series of identical on‐resonance RF pulses, such as would be experienced while imaging a single slice using a spoiled gradient echo sequence. The MT coupling terms for a two‐pool system were added to the Bloch equations and we derived the resulting steady‐state signal equation and compared this result to the conventional signal equation without MT effects. The steady‐state signal is increased by a few percent of the equilibrium magnetization because of MT. One consequence of this MT effect is inaccuracy in T1 values determined via conventional steady‐state gradient echo methods. (Theory predicts greater than 10% errors in T1 for white matter when using short TR.) A second consequence is the ability to quantify the relaxation and MT parameters by fitting the gradient echo steady state signal to the signal equation appropriately modified to include MT effects. The theory was tested in samples of MnCl 2, cross‐linked bovine serum albumin (BSA), and cross‐linked BSA + MnCl 2. Magn Reson Med, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic Resonance Imaging: Physical Principles and Sequence Design
Brown, R. W., Cheng, Y. N., Haacke, E. M., Thompson, M. R., & Venkatesan, R. (2014) · doi:10.1002/9781118633953 · Cited by 2,688
Cited by
Alexander, A. L., Hurley, S. A., Samsonov, A. A., Adluru, N., Hosseinbor, A. P., Mossahebi, P., Tromp, D. P. M., Zakszewski, E., & Field, A. S. (2011) · Brain Connectivity · doi:10.1089/brain.2011.0071 · Cited by 449
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422
Helms, G., Dathe, H., Kallenberg, K., & Dechent, P. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21732 · Cited by 332
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285
MRI‐based myelin water imaging: A technical review
Alonso‐Ortiz, E., Levesque, I. R., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25198 · Cited by 285
Yarnykh, V. L. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22394 · Cited by 170
“The cross-relaxation effect was recently shown as another ‘‘hidden’’ cause of bias in VFA T1 measurements (40).”
BackgroundYarnykh, V. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23224 · Cited by 162
“This bias may result in relative R1 errors on the order of MPF at short TR typically used in VFA measurements (42).”
BackgroundJanve, V. A., Zu, Z., Yao, S.-Y., Li, K., Zhang, F. L., Wilson, K. J., Ou, X., Does, M. D., Subramaniam, S., & Gochberg, D. F. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.02.034 · Cited by 119
Self-citationOn the inherent precision of mcDESPOT
Lankford, C. L., & Does, M. D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24241 · Cited by 83
Metadata
- Authors
- Ou, X., & Gochberg, D. F.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-02-26
- Volume
- 59
- Issue
- 4
- Pages
- 835-845
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2084050824
- Cited by
- 61
- References
- 1
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.