The DOI matches its Crossref record.
Quantitative MR susceptibility mapping using piece‐wise constant regularized inversion of the magnetic field
Open accessAbstract
Magnetic properties characterized by susceptibility and chemical shift linearly modify the local magnetic field experienced by spins. A piece‐wise constant solution using magnetic resonance imaging is found to the challenging inversion problem from field to magnetic properties. The magnetic field shifts were estimated from MR phase images. The MR magnitude images were segmented into many regions of uniform magnetic properties. Standard linear regression using the calculated magnetic field from each region allowed accurate susceptibility quantification. The technique was experimentally validated on a variety of samples including water, vegetable oil, air, Gadolinium, and superparamagnetic iron oxides. Susceptibility was measured with a precision better than 0.1 ppm, in a range of 10 ppm. In vivo feasibility was shown on the forearm for which soft‐tissue, cortical bone, and bone marrow susceptibility, and chemical shift values in good agreement with literature data were obtained. Magn Reson Med 60:1003–1009, 2008. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Susceptibility-Weighted Imaging: Technical Aspects and Clinical Applications, Part 1
Haacke, E. M., Mittal, S., Wu, Z., Neelavalli, J., & Cheng, Y.-C. N. (2009) · American Journal of Neuroradiology · doi:10.3174/ajnr.a1400 · Cited by 1,113
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Liu, C., Li, W., Tong, K. A., Yeom, K. W., & Kuzminski, S. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24768 · Cited by 503
Metadata
- Authors
- de Rochefort, L., Brown, R., Prince, M. R., & Wang, Y.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2008-09-24
- Volume
- 60
- Issue
- 4
- Pages
- 1003-1009
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2096111103
- Cited by
- 293
- References
- 0
- FWCI
- 8.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative MR susceptibility mapping using piece‐wise constant regularized inversion of the magnetic field. https://app.cochat.ai/papers/10.1002/mrm.21710
- The paper
- de Rochefort, L., Brown, R., Prince, M. R., & Wang, Y. (2008). Quantitative MR susceptibility mapping using piece‐wise constant regularized inversion of the magnetic field. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.21710
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.