Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record.

96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation

Open access
Wiggins, Graham C., Polimeni, Jonathan R., Potthast, Andreas, Schmitt, Melanie, Alagappan, Vijay, Wald, Lawrence L.·2009·Magnetic Resonance in Medicine

Abstract

The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive‐only phased‐array head coil with 96 receive elements constructed on a close‐fitting helmet‐shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal‐to‐noise ratio (SNR) loss, including various sources of coil loading and coupling between the array elements. The SNR and noise amplification (g‐factor) in accelerated imaging were quantitatively evaluated in phantom and human imaging and compared to a 32‐channel array built on an identical helmet‐shaped former and to a larger commercial 12‐channel head coil. The 96‐channel coil provided substantial SNR gains in the distal cortex compared to the 12‐ and 32‐channel coils. The central SNR for the 96‐channel coil was similar to the 32‐channel coil for optimum SNR combination and 20% lower for root‐sum‐of‐squares combination. There was a significant reduction in the maximum g‐factor for 96 channels compared to 32; for example, the 96‐channel maximum g‐factor was 65% of the 32‐channel value for acceleration rate 4. The performance of the array is demonstrated in highly accelerated brain images. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/mrm.22028

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 274

Metadata

Authors
Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L.
Venue
Magnetic Resonance in Medicine
Publisher
Wiley
Published
2009-07-21
Volume
62
Issue
3
Pages
754-762
ISSN
  • 0740-3194 (ISSN-L)
  • 1522-2594
OpenAlex
W2132996223
Cited by
274
References
0
FWCI
13.39
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation. https://app.cochat.ai/papers/10.1002/mrm.22028
The paper
Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L. (2009). 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22028

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.