The DOI matches its Crossref record.
96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation
Open accessAbstract
The benefits and challenges of highly parallel array coils for head imaging were investigated through the development of a 3T receive‐only phased‐array head coil with 96 receive elements constructed on a close‐fitting helmet‐shaped former. We evaluated several designs for the coil elements and matching circuitry, with particular attention to sources of signal‐to‐noise ratio (SNR) loss, including various sources of coil loading and coupling between the array elements. The SNR and noise amplification (g‐factor) in accelerated imaging were quantitatively evaluated in phantom and human imaging and compared to a 32‐channel array built on an identical helmet‐shaped former and to a larger commercial 12‐channel head coil. The 96‐channel coil provided substantial SNR gains in the distal cortex compared to the 12‐ and 32‐channel coils. The central SNR for the 96‐channel coil was similar to the 32‐channel coil for optimum SNR combination and 20% lower for root‐sum‐of‐squares combination. There was a significant reduction in the maximum g‐factor for 96 channels compared to 32; for example, the 96‐channel maximum g‐factor was 65% of the 32‐channel value for acceleration rate 4. The performance of the array is demonstrated in highly accelerated brain images. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Deshmane, A., Gulani, V., Griswold, M. A., & Seiberlich, N. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23639 · Cited by 606
Noble, S., Scheinost, D., & Constable, R. T. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116157 · Cited by 580
Neuroimaging of the periaqueductal gray: State of the field
Linnman, C., Moulton, E. A., Barmettler, G., Becerra, L., & Borsook, D. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.095 · Cited by 393
Noble, S., Spann, M. N., Tokoglu, F., Shen, X., Constable, R. T., & Scheinost, D. (2017) · Cerebral Cortex · doi:10.1093/cercor/bhx230 · Cited by 377
Quantitative magnetic resonance imaging of brain anatomy and in vivo histology
Weiskopf, N., Edwards, L. J., Helms, G., Mohammadi, S., & Kirilina, E. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00326-1 · Cited by 300
Metadata
- Authors
- Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2009-07-21
- Volume
- 62
- Issue
- 3
- Pages
- 754-762
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2132996223
- Cited by
- 274
- References
- 0
- FWCI
- 13.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation. https://app.cochat.ai/papers/10.1002/mrm.22028
- The paper
- Wiggins, G. C., Polimeni, J. R., Potthast, A., Schmitt, M., Alagappan, V., & Wald, L. L. (2009). 96‐Channel receive‐only head coil for 3 Tesla: Design optimization and evaluation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.