Modeling the influence of TR and excitation flip angle on the magnetization transfer ratio (MTR) in human brain obtained from 3D spoiled gradient echo MRI
Open accessThe DOI matches its Crossref record.
Abstract
Attempts to optimize the magnetization transfer ratio (MTR) obtained from spoiled gradient echo MRI have focused on the properties of the magnetization transfer pulse. In particular, continuous‐wave models do not explicitly account for the effects of excitation and relaxation on the MTR. In this work, these were modeled by an approximation of free relaxation between the radiofrequency pulses and of an instantaneous saturation event describing the magnetization transfer pulse. An algebraic approximation of the signal equation can be obtained for short pulse repetition time and small flip angles. This greatly facilitated the mathematical treatment and understanding of the MTR. The influence of inhomogeneous radiofrequency fields could be readily incorporated. The model was verified on the human brain in vivo at 3 T by variation of flip angle and pulse repetition time. The corresponding range in MTR was similar to that observed by a 4‐fold increase of magnetization transfer pulse power. Choice of short pulse repetition time and larger flip angles improved the MTR contrast and reduced the influence of radiofrequency inhomogeneity. Optimal contrast is obtained around an MTR of 50%, and noise progression is reduced when a high reference signal is obtained. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Quantitative multi-parameter mapping of R1, PD*, MT, and R2* at 3T: a multi-center validation
Weiskopf, N., Suckling, J., Williams, G., Correia, M. M., Inkster, B., Tait, R., Ooi, C., Bullmore, E. T., & Lutti, A. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00095 · Cited by 538
van Ewijk, H., Heslenfeld, D. J., Zwiers, M. P., Buitelaar, J. K., & Oosterlaan, J. (2012) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2012.01.003 · Cited by 377
Draganski, B., Ashburner, J., Hutton, C., Kherif, F., Frackowiak, R. S. J., Helms, G., & Weiskopf, N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.052 · Cited by 294
Self-citationCallaghan, M. F., Freund, P., Draganski, B., Anderson, E., Cappelletti, M., Chowdhury, R., Diedrichsen, J., FitzGerald, T. H. B., Smittenaar, P., Helms, G., et al. (2014) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2014.02.008 · Cited by 292
“This results in higher and more robust contrast in the brain than the MT ratio (Helms et al., 2010).”
BackgroundSelf-citationhMRI – A toolbox for quantitative MRI in neuroscience and clinical research
Tabelow, K., Balteau, E., Ashburner, J., Callaghan, M. F., Draganski, B., Helms, G., Kherif, F., Leutritz, T., Lutti, A., Phillips, C., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.01.029 · Cited by 256
Self-citationAdvanced MRI techniques to improve our understanding of experience-induced neuroplasticity
Tardif, C. L., Gauthier, C. J., Steele, C. J., Bazin, P.-L., Schäfer, A., Schaefer, A., Turner, R., & Villringer, A. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.047 · Cited by 127
MR g-ratio-weighted connectome analysis in patients with multiple sclerosis
Kamagata, K., Zalesky, A., Yokoyama, K., Andica, C., Hagiwara, A., Shimoji, K., Kumamaru, K. K., Takemura, M. Y., Hoshino, Y., Kamiya, K., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-50025-2 · Cited by 35
Metadata
- Authors
- Helms, G., Dathe, H., & Dechent, P.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-06-22
- Volume
- 64
- Issue
- 1
- Pages
- 177-185
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2169709398
- Cited by
- 70
- References
- 0
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.