Metric optimized gating for fetal cardiac MRI
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Phase‐contrast magnetic resonance imaging can be used to complement echocardiography for the evaluation of the fetal heart. Cardiac imaging typically requires gating with peripheral hardware; however, a gating signal is not readily available in utero. No successful application of existing technologies to human fetal phase‐contrast magnetic resonance imaging has been reported to date in the literature. The purpose of this work is to develop a technique for phase‐contrast magnetic resonance imaging of the fetal heart that does not require measurement of a gating signal. Metric optimized gating involves acquiring data without gating and retrospectively determining the proper reconstruction by optimizing an image metric. The effects of incorrect gating on phase contrast images were investigated, and the time‐entropy of the series of images was found to provide a good measure of the level of corruption. The technique was validated with a pulsatile flow phantom, experiments with adult volunteers, and in vivo application in the fetal population. Images and flow curves from these measurements are presented. Additionally, numerical simulations were used to investigate the degree to which heart rate variability affects the reconstruction process. Metric optimized gating enables imaging with conventional phase‐contrast magnetic resonance imaging sequences in the absence of a gating signal, permitting flow measurements in the great vessels in utero. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WRITING GROUP MEMBERS, Lloyd-Jones, D., Adams, R., Carnethon, M., De Simone, G., Ferguson, T. B., Flegal, K., Ford, E., Furie, K., Go, A., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.191261 · Cited by 3,140
Limperopoulos, C., Tworetzky, W., McElhinney, D. B., Newburger, J. W., Brown, D. W., Robertson, R. L., Guizard, N., McGrath, E., Geva, J., Annese, D., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.865568 · Cited by 663
Congenital Diseases of the Heart: Clinical‐Physiological Considerations
Rudolph, A. M. (2009) · doi:10.1002/9781444311822 · Cited by 212
Cited by
Donofrio, M. T., Moon-Grady, A. J., Hornberger, L. K., Copel, J. A., Sklansky, M. S., Abuhamad, A., Cuneo, B. F., Huhta, J. C., Jonas, R. A., Krishnan, A., et al. (2014) · Circulation · doi:10.1161/01.cir.0000437597.44550.5d · Cited by 1,275
Prsa, M., Sun, L., van Amerom, J., Yoo, S.-J., Grosse-Wortmann, L., Jaeggi, E., Macgowan, C., & Seed, M. (2014) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.113.001859 · Cited by 168
“Metric-optimized gating (MOG) is a retrospective technique that acquires temporally oversampled data and then iteratively sorts the data using hypothetical ECG trigger times until artifact in the associated images is minimized.(5,6) PC-MRI with MOG has been shown to be feasible in the late-gestation human fetus and va…”
MethodSelf-citationMoscatelli, S., Leo, I., Lisignoli, V., Boyle, S., Bucciarelli-Ducci, C., Secinaro, A., & Montanaro, C. (2023) · Children · doi:10.3390/children10050763 · Cited by 6
“, metric optimized gating, motion-corrected slice-volume registration) [15,30] and producing reliable CMR measurements other than additional anatomical information.”
Background
Metadata
- Authors
- Jansz, M. S., Seed, M., van Amerom, J. F. P., Wong, D., Grosse‐Wortmann, L., Yoo, S., & Macgowan, C. K.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-10-26
- Volume
- 64
- Issue
- 5
- Pages
- 1304-1314
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2111422238
- Cited by
- 109
- References
- 3
- FWCI
- 2.17
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.