The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Second order total generalized variation (TGV) for MRI
Open accessAbstract
Total variation was recently introduced in many different magnetic resonance imaging applications. The assumption of total variation is that images consist of areas, which are piecewise constant. However, in many practical magnetic resonance imaging situations, this assumption is not valid due to the inhomogeneities of the exciting B1 field and the receive coils. This work introduces the new concept of total generalized variation for magnetic resonance imaging, a new mathematical framework, which is a generalization of the total variation theory and which eliminates these restrictions. Two important applications are considered in this article, image denoising and image reconstruction from undersampled radial data sets with multiple coils. Apart from simulations, experimental results from in vivo measurements are presented where total generalized variation yielded improved image quality over conventional total variation in all cases. Magn Reson Med, 2011. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Cited by
Denoising of diffusion MRI using random matrix theory
Veraart, J., Novikov, D. S., Christiaens, D., Ades-aron, B., Sijbers, J., & Fieremans, E. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.08.016 · Cited by 1,905
Learning a variational network for reconstruction of accelerated MRI data
Hammernik, K., Klatzer, T., Kobler, E., Recht, M. P., Sodickson, D. K., Pock, T., & Knoll, F. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26977 · Cited by 1,713
Self-citationYang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
Diffusion MRI noise mapping using random matrix theory
Veraart, J., Fieremans, E., & Novikov, D. S. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26059 · Cited by 773
Knoll, F., Hammernik, K., Zhang, C., Moeller, S., Pock, T., Sodickson, D. K., & Akcakaya, M. (2020) · IEEE Signal Processing Magazine · doi:10.1109/msp.2019.2950640 · Cited by 403
Self-citation
Metadata
- Authors
- Knoll, F., Bredies, K., Pock, T., & Stollberger, R.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2010-12-08
- Volume
- 65
- Issue
- 2
- Pages
- 480-491
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2113030459
- Cited by
- 634
- References
- 1
- FWCI
- 15.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Second order total generalized variation (TGV) for MRI. https://app.cochat.ai/papers/10.1002/mrm.22595
- The paper
- Knoll, F., Bredies, K., Pock, T., & Stollberger, R. (2011). Second order total generalized variation (TGV) for MRI. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.22595
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.