The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
QUantitative Imaging of eXtraction of oxygen and TIssue consumption (QUIXOTIC) using venular‐targeted velocity‐selective spin labeling
Open accessAbstract
While oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO 2) are fundamental parameters of brain health and function, a robust MRI‐based mapping of OEF and CMRO 2 amenable to functional MRI (fMRI) has not been established. To address this issue, a novel method called QUantitative Imaging of eXtraction of Oxygen and TIssue Consumption, or QUIXOTIC, is introduced. The key innovation in QUIXOTIC is the use of velocity‐selective spin labeling to isolate MR signal exclusively from postcapillary venular blood on a voxel‐by‐voxel basis. Measuring the T2 of this venular‐targeted blood allows calibration to venular oxygen saturation (Yv) via theoretical and experimental T2 versus blood oxygen saturation relationships.Yv is converted to OEF, and baseline CMRO 2 is subsequently estimated from OEF and additional cerebral blood flow and hematocrit measurements. Theory behind the QUIXOTIC technique is presented, and implications of cutoff velocity (VCUTOFF) and outflow time parameters are discussed. Cortical gray matter values obtained with QUIXOTIC in 10 healthy volunteers are Yv= 0.73 ± 0.02, OEF = 0.26 ± 0.02, and CMRO 2= 125 ± 15 μmol/100 g min. Results are compared to global measures obtained with the T2 relaxation under spin tagging (TRUST) technique. The preliminary data presented suggest that QUIXOTIC will be useful for mapping Yv, OEF, and CMRO 2, in both clinical and functional MRI settings. Magn Reson Med, 2011. © 2011 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Cited by
The physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Wang, Y., Spincemaille, P., Liu, Z., Dimov, A., Deh, K., Li, J., Zhang, Y., Yao, Y., Gillen, K. M., Wilman, A. H., et al. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25693 · Cited by 273
Exploring early human brain development with structural and physiological neuroimaging
Vasung, L., Abaci Turk, E., Ferradal, S. L., Sutin, J., Stout, J. N., Ahtam, B., Lin, P.-Y., & Grant, P. E. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.041 · Cited by 177
Non-invasive imaging of oxygen extraction fraction in adults with sickle cell anaemia
Jordan, L. C., Gindville, M. C., Scott, A. O., Juttukonda, M. R., Strother, M. K., Kassim, A. A., Chen, S.-C., Lu, H., Pruthi, S., Shyr, Y., et al. (2016) · Brain · doi:10.1093/brain/awv397 · Cited by 104
Metadata
- Authors
- Bolar, D. S., Rosen, B. R., Sorensen, A. G., & Adalsteinsson, E.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2011-06-14
- Volume
- 66
- Issue
- 6
- Pages
- 1550-1562
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W1496298434
- Cited by
- 163
- References
- 1
- FWCI
- 9.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.