The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Coil compression for accelerated imaging with Cartesian sampling
Open accessAbstract
MRI using receiver arrays with many coil elements can provide high signal‐to‐noise ratio and increase parallel imaging acceleration. At the same time, the growing number of elements results in larger datasets and more computation in the reconstruction. This is of particular concern in 3D acquisitions and in iterative reconstructions. Coil compression algorithms are effective in mitigating this problem by compressing data from many channels into fewer virtual coils. In Cartesian sampling there often are fully sampled k‐space dimensions. In this work, a new coil compression technique for Cartesian sampling is presented that exploits the spatially varying coil sensitivities in these nonsubsampled dimensions for better compression and computation reduction. Instead of directly compressing in k‐space, coil compression is performed separately for each spatial location along the fully sampled directions, followed by an additional alignment process that guarantees the smoothness of the virtual coil sensitivities. This important step provides compatibility with autocalibrating parallel imaging techniques. Its performance is not susceptible to artifacts caused by a tight imaging field‐of‐view. High quality compression of in vivo 3D data from a 32 channel pediatric coil into six virtual coils is demonstrated. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Self-citationSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Roemer, P. B., Edelstein, W. A., Hayes, C. E., Souza, S. P., & Mueller, O. M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160203 · Cited by 2,322
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐space
Lustig, M., & Pauly, J. M. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22428 · Cited by 822
Self-citationOtazo, R., Kim, D., Axel, L., & Sodickson, D. K. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22463 · Cited by 571
Signal‐to‐noise measurements in magnitude images from NMR phased arrays
Constantinides, C. D., Atalar, E., & McVeigh, E. R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380524 · Cited by 510
Accelerating SENSE using compressed sensing
Liang, D., Liu, B., Wang, J., & Ying, L. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22161 · Cited by 474
Array compression for MRI with large coil arrays
Buehrer, M., Pruessmann, K. P., Boesiger, P., & Kozerke, S. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21237 · Cited by 257
Cited by
Echols, J. T., Wang, S., Patel, A. R., Hogwood, A. C., Abbate, A., & Epstein, F. H. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30285 · Cited by 9
Metadata
- Authors
- Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-04-09
- Volume
- 69
- Issue
- 2
- Pages
- 571-582
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2003271614
- Cited by
- 273
- References
- 15
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coil compression for accelerated imaging with Cartesian sampling. https://app.cochat.ai/papers/10.1002/mrm.24267
- The paper
- Zhang, T., Pauly, J. M., Vasanawala, S. S., & Lustig, M. (2013). Coil compression for accelerated imaging with Cartesian sampling. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24267
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.