The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Intravoxel incoherent motion MR imaging for prostate cancer: An evaluation of perfusion fraction and diffusion coefficient derived from different b‐value combinations
Open accessAbstract
There has been a resurgent interest in intravoxel incoherent motion (IVIM) MR imaging to obtain perfusion as well as diffusion information on lesions, in which the diffusion was modeled as Gaussian diffusion. However, it was observed that this diffusion deviated from expected monoexponential decay at high b‐values and the reported perfusion in prostate is contrary to the findings in dynamic contrast‐enhanced (DCE) MRI studies and angiogenesis. Thus, this work is to evaluate the effect of different b‐values on IVIM perfusion fractions (f) and diffusion coefficients (D) for prostate cancer detection. The results show that both parameters depended heavily on the b‐values, and those derived without the highest b‐value correlated best with the results from DCE‐MRI studies; specifically, f was significantly elevated (7.2% vs. 3.7%) in tumors when compared with normal tissues, in accordance with the volume transfer constant (Ktrans; 0.39 vs. 0.18 min−1) and plasma fractional volume (vp; 8.4% vs. 3.4%). In conclusion, it is critical to choose an appropriate range of b‐values in studies or include the non‐Gaussian diffusion contribution to obtain unbiased IVIM measurements. These measurements could eliminate the need for DCE‐MRI, which is especially relevant in patients who cannot receive intravenous gadolinium‐based contrast media. Magn Reson Med, 2013. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jensen, J. H., Helpern, J. A., Ramani, A., Lu, H., & Kaczynski, K. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20508 · Cited by 2,488
MRI quantification of non-gaussian water diffusion by kurtosis analysis
Jensen, J. H., & Helpern, J. A. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1518 · Cited by 1,251 · cited 3×
“However, the molecular diffusion was shown to depart from conventional random diffusion process at very high b-values because of the existence of barriers within cellular complex environments, leading to observed deviations from a simple monoexponential diffusion decay (11).”
BackgroundMethodInfluentialNiendorf, T., Dijkhuizen, R. M., Norris, D. G., van Lookeren Campagne, M., & Nicolay, K. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360607 · Cited by 570
Cited by
Clinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Andreou, A., Koh, D. M., Collins, D. J., Blackledge, M., Wallace, T., Leach, M. O., & Orton, M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2604-1 · Cited by 287
Metadata
- Authors
- Pang, Y., Turkbey, B., Bernardo, M., Kruecker, J., Kadoury, S., Merino, M. J., Wood, B. J., Pinto, P. A., & Choyke, P. L.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-04-09
- Volume
- 69
- Issue
- 2
- Pages
- 553-562
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2094485109
- Cited by
- 189
- References
- 3
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intravoxel incoherent motion MR imaging for prostate cancer: An evaluation of perfusion fraction and diffusion coefficient derived from different b‐value combinations. https://app.cochat.ai/papers/10.1002/mrm.24277
- The paper
- Pang, Y., Turkbey, B., Bernardo, M., Kruecker, J., Kadoury, S., Merino, M. J., Wood, B. J., Pinto, P. A., & Choyke, P. L. (2013). Intravoxel incoherent motion MR imaging for prostate cancer: An evaluation of perfusion fraction and diffusion coefficient derived from different b‐value combinations. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24277
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.