The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Open accessAbstract
For patients with impaired breath‐hold capacity and/or arrhythmias, real‐time cine MRI may be more clinically useful than breath‐hold cine MRI. However, commercially available real‐time cine MRI methods using parallel imaging typically yield relatively poor spatio‐temporal resolution due to their low image acquisition speed. We sought to achieve relatively high spatial resolution (∼2.5 × 2.5 mm 2) and temporal resolution (∼40 ms), to produce high‐quality real‐time cine MR images that could be applied clinically for wall motion assessment and measurement of left ventricular function. In this work, we present an eightfold accelerated real‐time cardiac cine MRI pulse sequence using a combination of compressed sensing and parallel imaging (k‐t SPARSE‐SENSE). Compared with reference, breath‐hold cine MRI, our eightfold accelerated real‐time cine MRI produced significantly worse qualitative grades (1–5 scale), but its image quality and temporal fidelity scores were above 3.0 (adequate) and artifacts and noise scores were below 3.0 (moderate), suggesting that acceptable diagnostic image quality can be achieved. Additionally, both eightfold accelerated real‐time cine and breath‐hold cine MRI yielded comparable left ventricular function measurements, with coefficient of variation <10% for left ventricular volumes. Our proposed eightfold accelerated real‐time cine MRI with k–t SPARSE‐SENSE is a promising modality for rapid imaging of myocardial function. J. Magn. Reson. Imaging 2013. © 2012 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Levy, D., Garrison, R. J., Savage, D. D., Kannel, W. B., & Castelli, W. P. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005313222203 · Cited by 5,699
Cited by
Feng, L., Grimm, R., Block, K. T., Chandarana, H., Kim, S., Xu, J., Axel, L., Sodickson, D. K., & Otazo, R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24980 · Cited by 718
Self-citationFeng, L., Axel, L., Chandarana, H., Block, K. T., Sodickson, D. K., & Otazo, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25665 · Cited by 667
Self-citationFast 3D magnetic resonance fingerprinting for a whole‐brain coverage
Ma, D., Jiang, Y., Chen, Y., McGivney, D., Mehta, B., Gulani, V., & Griswold, M. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26886 · Cited by 158
Metadata
- Authors
- Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2012-08-06
- Volume
- 70
- Issue
- 1
- Pages
- 64-74
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2133782326
- Cited by
- 232
- References
- 2
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE. https://app.cochat.ai/papers/10.1002/mrm.24440
- The paper
- Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013). Highly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.24440
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.